18
EtherWAN Series Router Hardware Installation Guide
Deployment Modes
Deployment Modes
Fixed Installation without I/O
For fixed installations, connect the wires as shown in the figure below. You can configure
Low Volt-age Standby Mode (LVS) to force the into Standby mode when the voltage is
low. Voltage is moni-tored on Pin 3 and 4.
•
Pin 1 (Power)—Use the Red wire in the DC cable to connect Pin 1 to the power
source. Include a 4.0A fast acting fuse to the input line. A continuous (unswitched)
DC power source is recommended.
•
Pin 2 (Ground)—Use the Black wire in the DC cable to connect Pin 2 to Ground.
•
Pin 3 (IGN - Ignition)—Connect to Power for voltage sensing.
Recommended Vehicle Installation (Ignition Mode)
For vehicle installations, connect the white IGN wire to the vehicle’s ignition switch as
shown in the diagram below. This allows the to operate with the vehicle. When the
vehicle’s ignition is off the can enter standby mode. You can configure a time delay
between the vehicle’s ignition shuts off, and the time the should go into standby mode. A
delayed standby is useful if you want to maintain a network connection while the vehicle’s
engine is shut off for short periods of time, such as in a delivery vehi-cle.
•
Pin 1 (Power)—Use the Red wire in the DC cable to connect Pin 1 to the power
source. Include a 4.0 fast acting fuse in the input power line. continuous
(unswitched) DC power source is recommended.
•
Pin 2 (Ground)—Use the Black wire in the DC cable to connect Pin 2 to Ground.
•
Pin 3 (IGN - Ignition)—It is recommended to use the IGN wire (Pin 3) to initiate
standby mode on the .