Only  specially  trained  and  authorized  technicians  are
permitted  to  service  this  water  heater.

Unpack  the  unit  carefully  and  make  sure  that  all

accessories  are  put  aside  so  that  they  will  not  be
lost.

Operator's  manual

Warranty  Card

Additional  Parts

I

nspect  the  water  heater  for  possible  shipping

damages.

Installation  Preparation

PROFESSIONAL INSTALLATION REQUIRED

Unpacking Your Eternal Water Heater

Ÿ
Ÿ
Ÿ

Check the markings of the rating plate on the water
heater to  be certain the  type of gas being furnished

corresponds to what the water heater is equipped for.

Do not 

connect this water heater to a fuel type not in

accordance with the rating plate

WATER HEATER PLACEMENT

Additional Safety Instructions

Carefully choose the location for the new heater as
placement is a  very important  consideration for  the

safety of the occupants in the building and for the most
economical use of the appliance.

Whether replacing an old water heater or putting the
water heater in a new location, consider the following
critical points:

The location  selected should be  as close to the
vent termination point as possible, and centered
within the water piping system for best hot water

delivery. All water heaters can leak. Do not install
without adequate drainage provisions where wa-
ter flow can cause property damage.

If vented through an outside wall or through the roof
using 4" vent piping the total vent run cannot ex-
ceed 30 feet with one 90 elbow. If more elbows are
required the venting distance must be reduced 5
feet for every 90  elbow.

1.

3.

4.

2.

Vent piping cannot slope upward and horizontal
runs require 1/4'' per foot rise. All horizontal runs
require adequate support at 3 1/2 foot intervals and

vertical runs supported at 5 feet intervals.

Condensation may be created at times as the com-

bustion gases exit the vent cap. Discoloration of sur-
faces in proximity to the vent cap may occur.

 CAUTION

!

!

Before  commencing  the  Installation

Check  that  it  is  in  accordance  with  relevant  building
and  mechanical  codes,  as  well  as  any  local  or  state

or  federal  regulations.

For  other  than  direct  vent  appliance,  the  appliance
must  be located  as  close  as  possible  to a  chimney

or  gas  vent.

The appliance  should  be  located  in  an  area  where
leakage  of  the  tank  or  connections  will  not  result

in  damage  to  the  area  adjacent  to  the  appliance
or  to  lower  floors  of  the  structure.  When  such
locations  cannot  be  avoided,  it  is  recommended

that  a  suitable  drain  pan  be  installed  under  the
appliance.  The  pan  must  not  restrict  combustion
air  flow.

The  minimum  inlet  gas  pressure  must  be  within
the  value  specified  by  the  manufacturer  and  the
minimum  value  listed  is  only  for  the  purpose  of

input  adjustment.

If  a  water heater  is  installed in  closed  water supply
system,  such  as  one  having  a  backflow  preventer

in  the  cold  water  supply  line and  a thermal  expan-
sion  tank  is  required, contact  the  water  supplier  or
local  plumbing  inspector  on  how  to  control  this

situation.

The Temperature and  Pressure (T&P) relief  valve
must be certified as meeting the requirement of the
Standard for Relief Valves and Automatic Gas Shut-
off Devices for Hot Water Supply Systems ANSI Z21.
22 /CAN1-4.4.The valve must be marked with a maxi-
mum set pressure not to exceed the marked hydro-
static working pressure of the water heater (150 psi)
and  a  discharge  capacity not  less than  the water
heater input rate as marked on the rating plate.

For  tube  type  water  heaters,  the  relief  valve  must

be  installed  near  the  hot  water  outlet.

For  tube  type  circulating  water  heaters,  installed

only  with  a  pressure  relief  valve,  the  separate
storage  vessel  must  have  a  temperature  and  relief
valve  installed.  This  relief  valve  shall  comply  with

the  Standards  for;  "Relief  Valves  and  Automatic
Gas Shutoff Devices for Hot Water Supply Systems".

 WARNING

!

!

3.

2.

1. Read the Safety guidelines in the beginning of this

manual.

The internal computer controlled regulator is pre-
set by the manufacturer and should not be adjusted

by user.

Maintain proper space around the unit for servicing.
Install the unit so that it can be connected or re-

moved easily.

The  electrical  connection  requires  a  means for
switching off the power supply.

Avoid installing the unit in an area with high levels

of dust, sand, or debris. These particles may clog
the air vent or impair the function of the fan, leading
to improper combustion. Regular maintenance is
needed.

Do not install  the unit where the  exhaust vent is

pointing into any opening in a building or where the
noise may disturb neighbors.

4.

5.

6.

Ÿ

Ÿ

Ÿ

Ÿ

Ÿ

Ÿ

Содержание GU26DV

Страница 1: ...ay WARNING California Proposition 65 lists chemical substances known to the state to cause cancer birth defects death serious illness or other reproductive harm This product may contain such substance...

Страница 2: ...be filled with water Water must be running from the hot water faucet before turning the main gas valve to the water heater to ON WARNING CAUTION If you do not follow these instructions exactly a fire...

Страница 3: ...al gas valve located on the outside of the unit to the off position Wait five 5 minutes to clear out any gas If you smell gas STOP Follow B in the safety information above If you don t smell gas go to...

Страница 4: ...4 Parts Diagrams for Model GU32DV 505 11 12 1321...

Страница 5: ...06 1 7 Panel Bottom 151010009 1 8 Control Panel Assembly 301080170 1 9 Temperature and Pressure Relief Valve 194010281 1 10 Intake Collar Assembly 307060517 1 11 Top Packing 151010200 1 12 Plug 601020...

Страница 6: ...Parts Diagrams for Model GU26DV 505 11 12 1261 6...

Страница 7: ...06 1 7 Panel Bottom 151010009 1 8 Control Panel Assembly 301080170 1 9 Temperature and Pressure Relief Valve 194010281 1 10 Intake Collar Assembly 307060517 1 11 Top Packing 151010200 1 12 Plug 601020...

Страница 8: ...will turn off automatically WHATTO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier fro...

Страница 9: ...re Press the HOT or COLD Temperature Setting Button with unit ON Temperature setting is only adjustable when the water heater is not in use The maximum water temperature setting can be limited by DIP...

Страница 10: ...a self cleaning system initiated by the flow of water Build up of sediment in faucet aerators shower heads and screens could impair water flow and cause the water heater to deliver less than its full...

Страница 11: ...n A secondary air hole thermistor short open A vent condition is not normal Temperature too high on a burner thermistor Mixing control valve is not connected Mixing control valve initialization failur...

Страница 12: ...bove sea level contact the manufacturer for high 0 5 to 9 1 Gal min 100 102 104 106 108 110 112 114 116 122 131 140 149 158 167 F 15 steps 9 1 Gal min ITEM MODEL NAME TYPE IGNITION DIMENSIONS OPERATIO...

Страница 13: ...bs 120 VAC 60 Hz Specifications GU26DV 505 11 12 1261 Indoor Sealed Direct Vented Direct Ignition 13 Natural Gas Max 180 000 btu hr Min 47 500 btu hr L P Gas Max 180 000 btu hr Min 47 500 btu hr 45 F...

Страница 14: ...himney or gas vent The appliance should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the appliance or to lower floors of the structu...

Страница 15: ...Relief Valve x 1 Intake Top x 1 O Ring G95 x 1 Exhaust Collar x 1 Valve Adaptor x 1 Orifice for LPG x 1 LPG Label x 1 Top Packing x 1 Mesh Screen x 2 Self Tapping Screw T4x16 x 5 Philips Head Screw M...

Страница 16: ...4 screws Install the T P Relief Valve on the side of unit Make sure the T P Relief is secured tight to prevent water leak For indoor installation please install the Top Packing before connecting PVC o...

Страница 17: ...xhaust outlet and air inlet terminals shall terminate at least 18 inches above the roof surface 0 clearance for 4 PVC ABS OR CPVC Schedule 40 piping from combustible surfaces The venting system must b...

Страница 18: ...cal or Horizontal run in Length 40 ft Power Direct Venting Rule 18 When determining the installation location for a power direct vent water heater snow accumulation and drifting should be considered i...

Страница 19: ...haust gases The venting system must be installed in a manner which allows inspection during the installation of the venting pipes and joints as well as periodic inspec tion after installation as requi...

Страница 20: ...ional Standard Institute and Ameri can Society for Testing and Materials ANSI ASTM stan dards in the United States CEMENTING PVC ABS or CPVC PIPE and FITTING All primers cleaners and cements must meet...

Страница 21: ...om the center line of the terminal E 12 inch min clearance to unventilated soffit F Clearance to outside corner G 2 feet clearance to inside corner formed by two exterior walls H 4 feet clearance to e...

Страница 22: ...o the left Complete the rest of the vent pipe installation to thewaterheater sventconnector fittingontheblower outlet If necessary support horizontal run as previously mentioned The vertical inlet and...

Страница 23: ...3 7 9 3 4 7 3 2 3 3 0 8 2 7 6 2 5 3 2 1 3 1 1 4 2 2 0 6 1 4 9 7 1 2 1 3 1 0 4 0 9 1 4 8 3 5 7 7 2 7 2 5 6 7 8 6 3 1 5 6 7 5 1 1 4 4 0 1 1 2 3 3 0 8 2 3 0 0 1 8 5 9 1 5 6 0 1 4 1 8 1 2 7 6 1 1 8 2 1 0...

Страница 24: ...Be careful not to reverse the hot water outlet and cold water supply line connections to the water heater This will cause your heater to operate dan gerously and void warranty Make sure the hot and c...

Страница 25: ...ions in the State of California CAUTION California Law requires that residential water heaters must be braced anchored or strapped to resist falling or horizontal displacement due to earthquake motion...

Страница 26: ...be electrically grounded Label all wires prior to disconnection when servic ing controls Wiring error can cause improper and dangerous operation Verify proper operation after servicing CAUTION The wa...

Страница 27: ...28 PV switch 5 OFF switch 4 Test selection switch 2 switch 3 Temperature selection 1 switch 2 Temperature selection 2 switch 1 Temperature selection 3 O N 8 7 6 5 4 3 2 1 switch 8 Reserved switch 7 Re...

Страница 28: ...m axim umtem perature by selection switch O N 3 2 1 104 O N 3 2 1 110 O N 3 2 1 114 O N 3 2 1 122 O N 3 2 1 131 O N 3 2 1 140 O N 3 2 1 149 O N 3 2 1 167 Limitation of maximum temperature by selection...

Страница 29: ...2 screws securing the Control Panel Assem bly to the frame and remove the Assembly from Water Heater Loosen 2 screw and the nut of the gas pipe and insert with Orifice LP Tighten the loose nut to mak...

Страница 30: ...Valve Adaptor LP Reverse the steps above by reassembling the packing Gas Flange and Connector Bracket Make sure all screws and secure and tightened Change Dip Switch No 8 position from left to right 8...

Страница 31: ...31 Recirculation System With A Grand Hall Water Heater Do not run circulation pump over two hours when install with timer Pump on time is should be less than two hours CAUTION...

Страница 32: ...You are responsible for shipping charges of such replacement parts This Warranty does not cover any failures or operating difficulties due to accident abuse misuse alteration misapplica tion vandalis...

Отзывы: