8
This water heater does not have a pilot. It is equipped
with an ignition device which automatically lights the
burner. Do not try to light the burner manually.
Before operating, make sure that a gas leak is not evi-
dent by smelling the area around the unit. Be sure to
smell next to the floor because gas is heavier than air
and will settle on the floor.
Use only hand to turn the gas valve knob. Never use
tools. If the knob will not turn by hand, do not try to repair
it, call a qualified service technician. Force or attempted
repair could result in a fire or explosion due to the gas
leakage.
Do not use this water heater if any part has been under
water. Immediately call a qualified service technician to
inspect the water heater and to replace any parts that
have been under water.
Do not install the unit standing directly on combus-
tible surface.
Operating Instructions
STARTING THE SYSTEM
For your safety, read before operating
NORMAL OPERATION
To turn on your water heater
STARTING UP
Once the unit has been properly installed, check the gas and
water connections for leaks.
Check for proper ventilation and combustible air supply to
the water heater. Purge the gas and water lines to remove
debris; then follow these steps to turn on your unit.
To turn off your water heater
1. Close the hot water tap and the water heater's burner
will turn off automatically.
WHAT TO DO IF YOU SMELL GAS
-Do not
try to light any appliance.
-Do not
touch any electrical switch.
-Do not
use any phone in your building.
-Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
-If you cannot reach your gas supplier, call the fire
department.
Open a hot water tap.
Burner will ignite; the indicator will light on front controller.
Mix cold water to get the desired water temperature at tap.
Maximum temperature of hot outlet can be set by controller
on the front of the unit.
Close the manual gas shut-off valve located on the
gas line.
Fully open the manual water shut-off valve on the wa-
ter supply line.
To ensure complete filling of the heat exchanger tank,
allow air to exit by opening the nearest hot water faucet.
Allow water to run until a constant flow is obtained.
This will let air out of the water heater and piping.
Open a hot water tap, to check that water will flow to
that tap. Then close the hot water tap.
Fully open the manual shut-off gas valve.
Plug in the 120 VAC/60Hz power supply to the water
heater and turn on the unit.
Open tap and enjoy endless hot water!
1.
2.
3.
4.
5.
6.
7.
Never use this hot water heater unless it is
completely filled with water.
The tank must be filled with water. Water must flow
from the hot water faucet before turning "ON" gas to
the water heater.
!
!
CAUTION
Do not drink water that has been inside the unit
for extended period of time. Do not drink the first
use of hot water from the unit in the morning.
!
!
CAUTION
1.
2.
3.
4.