background image

36

Grand Hall Limited Warranty

Product Line 

GU125T & GU160T
Note: GU125T/GU160T models are solely for Residential Application* and the warranty is voided if used for any 
use other than Residential Application*.  *See 

DEFINITIONS

 below.

General Terms of Limited Warranty for Product

Grand Hall will warrant to the purchaser of this gas water heater (the 

Product

) at the original installed location 

for Residential Application* that it will be free of defects in material, workmanship and performance when used 
with Potable Water* and non-Hard Water* and when installed and used in strict compliance with Grand Hall

speci

 cations, for the applicable period shown in Warranty Periods below.  *See 

DEFINITIONS

 below.

Warranty Exclusions

This Product warranty does not apply in the event of Product failure, operating dif

 culties or damage to the Product 

due to a failure to follow the instructions in the Installation Operation Manual (

Manual

) or as a result of abuse, misuse, 

Misapplication*, Product modification, faulty ancillary equipment, improper voltage or current, lightning or other acts 
of God, Non-Residential Application, use of non-Potable Water*, use of Hard Water*, normal wear and tear, Improper 
Installation*, vandalism, or lack of maintenance or service, severe weather or exposure to chemicals, either directly or in 
the atmosphere (de

 ned collectively as 

Damage

).  *See 

DEFINITIONS

 below.

This warranty only applies to the original installation of the Product by a licensed contractor.  This warranty does not 
apply if the Product is relocated, or re-installed. This warranty does not apply if the Product is purchased over the 
internet. This warranty does not apply if the Product is used outside of the United States of America.

Damage caused by environmental conditions outside of normal Product specifications such as gas pressure, water 
quality, piping materials, pump sizing, wind level, and operating noise complaints are not covered by this warranty.  See 
the Manual for additional details.

This Warranty does not apply when the Product is used with recirculation system for hot water on demand is installed 
unless external aquastat, or timer controls and a thermal expansion tank are installed and properly and properly used.

Exclusive Remedy

Your exclusive remedy under this Warranty is replacement or repair of the Product at Grand Hall

s sole option. 

Replacement Products shall be installed by a licensed contractor and the replacement Product shall carry out 
the remainder of the warranty from the originally installed Product.

Proof of Purchase

Grand Hall will require reasonable proof of your purchase. Save your dated receipt in case it is required as proof 
of purchase. You may also show proof of purchase by registering within 30 days of purchasing the product at 

www.eternalwaterheater.com.

 Registration constitutes proof of purchase, but registration is not required in order 

to validate this warranty.

Limitation of Damages

Grand Hall

s entire liability under this warranty shall in no event exceed the purchase price for the Product, 

excluding any charges for installation. 

No Consequential or Other Damages

Notwithstanding anything else in this warranty or otherwise, Grand Hall will not be liable with respect to the 
product under any legal theory, including without limitation contract, negligence, strict liability or other legal 
or equitable theory (i) for any amount in excess of the purchase price for the defective product, or (ii) for any 
general, consequential, punitive, incidental or special damages. These include damages from interruption of use, 
lost pro

 ts, the cost of the installation or removal of any products, the cost of installation of replacement products, 

and any costs of inspection, testing, or redesign caused by any defect, or caused by the repair or replacement 
of other products arising from a defect in any this product.  This section does not limit liability for bodily injury 
of a person. 

In the United States, some states do not allow the exclusion or limitation of incidental or 

consequential damages, so the above exclusion or limitation may not apply to you.  This warranty gives 
you speci

 c legal rights, and you may also have other rights which vary from state to state.

Содержание GU125T

Страница 1: ...Only specially trained and authorized personnel are permitted to service this water heater NOTE TO ASSEMBLER INSTALLER Leave this manual with the consumer NOTE TO CONSUMER Keep this manual for future...

Страница 2: ...l Horizontal Termination P20 21 Clearance Requirements from Vent Terminations to Building Openings P22 Multiple Units Termination P23 Vent Pipe Installation Terminator Position P24 Gas Supply Piping P...

Страница 3: ...3 Included Accessories Optional Accessories...

Страница 4: ...5 000 BTU Hr 100 000 BTU Hr Gas Supply Pressure NG LP 3 5 WC to 10 5 WC 8 WC to 14 WC Ignition System Direct Electronic Ignition w Automatic Flame Sensing Burner System Sealed Combustion with Metal Fi...

Страница 5: ...5 Dimensions GU125T 518 11 12 1125 GU160T 518 11 12 1160...

Страница 6: ...6 Dimensions GU125T 518 11 12 1125 GU160T 518 11 12 1160...

Страница 7: ...7 Dimensions GU125T 518 11 12 1125 GU160T 518 11 12 1160...

Страница 8: ...9 Exhaust Adaptor 152320028 20 Trap Clamp 151010032 21 Condensate Trap 332070125 22 Intake Air Pressure Switch 192320116 GU125T 192290098 GU160T 23 Exhaust Air Pressure Switch 192320117 GU125T 1922900...

Страница 9: ...quali ed service technician to inspect the water heater and to replace any damaged parts Far away from water heater In approved containers Tightly closed Out of children s reach Cannot be seen Vapors...

Страница 10: ...supply line and the result of thermal expansion can create a rapid and dangerous pressure increase in the water heater and system piping This rapid pressure increase can quickly reach the safety sett...

Страница 11: ...5 feet with one 90 elbow If more elbows are required the venting distance must be reduced 5 feet for every 90 elbow Condensation may be created at times as the combustion gases exit the vent cap Disco...

Страница 12: ...lation procedure Insert condensate trap into the exhaust adaptor and install trap clamp Place exhaust pipe inside exhaust adaptor socket bottom Then hold the exhaust pipe in place by attaching the pip...

Страница 13: ...tighten water pipe with pipe wrench Use Spanner to fix gas adaptor and then tighten gas pipe with pipe wrench Use spanner to fix valve and then tighten T P valve with pipe wrench Water Pipe Installati...

Страница 14: ...g area CAUTION The condensate drain line material must be an approved material by the authority having jurisdiction In absence of such authority PVC and CPVC piping must comply with ASTM D1785 or D284...

Страница 15: ...use of a condensate pump Size the pump to allow for a maximum condensate discharge of 2 GPH from the water heater Horizontal runs must be sloped 1 4 per foot towards the drain or condensate pump Be s...

Страница 16: ...ll appliances in the enclosed area When combustion air is supplied from inside the building each opening should give a minimum free area of one square inch per 1 000 Btu hour of the total input rating...

Страница 17: ...accordance with the above provisions should comply with NFPA 720 and be ANSI UL 2034 listed and CSA certified Signage A metal or plastic identification plate should be permanently mounted to the exter...

Страница 18: ...ng Systems ULC S636 Components of this listed system shall not be interchanged with other vent systems or unlisted pipe ttings All plastic components and speci ed primers and glues of the certi ed ven...

Страница 19: ...ve intake open How To Con gure Unit For Power Vent Maximum Allowable Vent and Combustion Air Piping Length 3 inch Piping Feet Max of 90 elbows 100 6 Reduce the maximum allowable length for each elbow...

Страница 20: ...Operation manual WARNING Through roof Power Vent Minimum twelve 12 inches above anticipated snow level The termination cannot be connected to an existing vent piping or chimney The total vertical and...

Страница 21: ...vent pipe or ttings with mortar or silicone caulk silicone caulk as show above Complete the rest of the vent pipe installation to the water heater s vent connector tting on the blower outlet If necess...

Страница 22: ...When Heater is Installed Indoors Maintain the following clearances to any opening in any building 4 below 4 horizontally from or 1 above any door operable window or gravity air inlet into any building...

Страница 23: ...mportant to avoid recirculation of flue gases Concentric Multivent Termination Horizontal Terminations Vertical Terminations Multiple Unit Termination Vertical Terminations Horizontal Terminations The...

Страница 24: ...Clearance to each side of center line extended above meter regulator assembly 3 feet within a height 15 feet above the meter regulator assembly I Clearance to service regulator vent outlet 3 feet J C...

Страница 25: ...ividual shut off valve must be isolated from the gas supply piping system by unplugging the unit and turning off the main gas valve during any pressure testing of the gas supply piping system at test...

Страница 26: ...nded sizing of piping tanks and 100 lockup gas regulator NOTICE 5 Prior to start up ensure the unit is set to re propane Check the rating label for the type of fuel If there is a con ict or doubt on t...

Страница 27: ...aining valve from the unit and clean the lter FILLING THE WATER DRAINING THE WATER Close the water heater drain valve by turning the knob to the right The drain valve is on the lower right side of the...

Страница 28: ...o protect from power surges Do not connect 220 240V AC to this unit It will damage the water heater and void the warranty Do not disconnect the power supply when the unit is in normal operation A batt...

Страница 29: ...red properly and compliant to Local and State Codes Pump control such as aquastat or timer must be used in recirculation applications or long burner runtime occur and cause premature failure Daily usa...

Страница 30: ...emperature delivered Contact a licensed professional for maintenance NOTICE Once the unit has been properly installed check the gas and water connections for leaks Check for proper ventilation and com...

Страница 31: ...ature should not be set higher than 120 F Please check with your local codes to ensure temperature is set properly CAUTION BURN 1 To switch the water heater ON from OFF condition press the Power Butto...

Страница 32: ...water insects rodents or other foreign materials such as fallen leaves and dust that could cause blockages Do not obstruct the ow of combustion air and exhaust air ow Water Strainer The water strainer...

Страница 33: ...tory and more Diagnostic Contents Example Explanation Outlet temperature Ot Ot 134 Outlet temperature is 134 F Hot water stored tank temperature Ht Ht 145 Tank temperature is 145 F Fan RPM Rp Rp 4500...

Страница 34: ...hout a service call Please quote the code displayed when inquiring about service NOTE In all cases you may be able to clear the Error Message simply by turning the hot water tap OFF then ON again If t...

Страница 35: ...35 Wiring and Connection Diagram Wiring Diagram MODEL GU125T 518 11 12 1125 GU160T 518 11 12 1160...

Страница 36: ...not apply when the Product is used with recirculation system for hot water on demand is installed unless external aquastat or timer controls and a thermal expansion tank are installed and properly and...

Страница 37: ...isregarding Grand Hall sizing recommendations power or direct venting with air intake exposed to contaminated environment solely closed loop space heating applications and uncontrolled or improperly s...

Страница 38: ...38 The stand assembly installation manual...

Страница 39: ...39 The stand assembly installation manual...

Отзывы: