Floor Mounting
For installation in California this water must be braced or anchored to avoid falling or moving during an earthquake. See
instructions for correct installation procedures. Instructions may be obtained form California Office of the State Architect.
1102 Q Street, Suite 5100, Sacramento, CA 95811.
FOR INSTALLATIONS IN THE STATE OF CALIFORNIA
INSTALLATION REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS
Massachusetts Code requires this water heater to be inatalled in accordance with Massachusetts 248-CMR 2.00: State
Plumbing Code and 248-CMR 5. See Commonwealth of Massachusetts below.
For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters
installed in every dwelling, buliding or structure used in whole or in part for residential purposes, including those owned
or operated by the Commonwealth and where the side wall exhaust vent terminations is less than seven (7) feet above
finished grade in the area of the venting, including but not limited to decks and porches, the following requirements should
be satisfied:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter should
observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where
the gas equipment is to be installed. In addition, the installing plumber or gasfitter should observe that a battery operated or
hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure
served by the sidewall horizontal vented gas fueled equipment. It should be the responsibility of the property owner to
secure the services of qualified licensed professionals for the installation of hard wired carbon momoxide detectors.
In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard
wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner
should have a period thirty(30) days to comply with the above requirements provided that during said thirty(30) day period,
a battery operated carbon monoxide detector with an alarm should be installed.
Approved Carbon Monoxide detectors
Each carbon monoxide detector as required in accordance with the above provisions should comply with NFPA 720 and be
ANSI/UL 2034 listed and CSA certified.
Signage
A metal or plastic identification plate should be permanently mounted to the exterior of the building at a minimum height
of eight(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating
appliance or equipment. The sign should read, in print size no less than one-half(1/2) inch in size. GAS VENT DIRECTLY
BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.
Inspection
The state or local gas inspector of the side wall horizontally vented gas fueled equipment should not spprove the installtion
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the
provisions of 248 CMR 5.08(2)(a) 1 through 4.
Exemptions:
The following equipment is exempt from 248 CMR 5.05(2)(a)1 through 4:
The equipment listed in Chapter 10 entitled Equipment Not Required To Be Vented in the most current edition of NFPA
54 as adopted by the Board; and
1.
Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the
dwelling, building, or structure used in whole or in part for residential purposes.
2.
Manufacturer Requirements- Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design
or venting system components with the equipment, the instructions provided by the manufacturer for installation of the
equipment and the venting system should include:
Detailed instructions for the installation of the venting system design or the venting system components; and
1.
A complete parts list for the venting system design or venting system.
2.
Manufacturer Requirements- Gas Equipment Venting System Not Provided
When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment dose not provide the
parts for venting the flue gases, but identifies special venting systems, the following requirement should be satisfied by the
manufacturer:
The referenced special venting system instructios should be included with the appliance or equipment installation
instructions; and
1.
The special venting systems should be Product Approved by the Board, and the instructions for that system should
include a parts list and detailed installation instructions.
2.
A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting
instructions, all parts lists for venting instructions, and/or all venting design instructions should remain with the appliance or
equipment at the completion of the installation.
Содержание GU125T
Страница 3: ...3 Included Accessories Optional Accessories...
Страница 5: ...5 Dimensions GU125T 518 11 12 1125 GU160T 518 11 12 1160...
Страница 6: ...6 Dimensions GU125T 518 11 12 1125 GU160T 518 11 12 1160...
Страница 7: ...7 Dimensions GU125T 518 11 12 1125 GU160T 518 11 12 1160...
Страница 35: ...35 Wiring and Connection Diagram Wiring Diagram MODEL GU125T 518 11 12 1125 GU160T 518 11 12 1160...
Страница 38: ...38 The stand assembly installation manual...
Страница 39: ...39 The stand assembly installation manual...