Special function introduction and application
The following functions are made to order in accordance with the special needs of
customers:
1
.
The O/S/C interfaces available
Add another O/S/C button to open or close the door.
2
.
Auto safety reverse function
This special function is for safety consideration. Reverse force and time are in accordance
with European Union standard.
(
F≤400N; reverse time≤0.75S
)
3. Flash light function
There are corresponding interfaces for this function and provide 24v-35v flash light voltage.
Connect the flash light with DC 24v-
28v, current≤100mA. When use AC 220V power flash
lights, please match an adapter, and wiring as required.
4. Pass door (SD) protection
This function ensure that the door can’t be opened unless the small pass door is closed.
The door panel won’t be damaged.
Fig. 1
Fig. 2
Содержание ET-1000E