background image

In-ground Swing Gate Operator

UL325 - UL991

770

FAAC International Inc.
Headquarter & East Coast Operations
3160 Murrell Road
Rockledge, FL 32955
Tel. 800 221 8278
www.faacusa.com

FAAC International Inc.

West Coast Operations

357 South Acacia Avenue

Fullerton, CA 92831

Содержание 770 COMPACT

Страница 1: ...UL325 UL991 770 FAAC International Inc Headquarter East Coast Operations 3160 Murrell Road Rockledge FL 32955 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Ac...

Страница 2: ...SPECIFICATIONS 6 1 1 Technical Specifications 6 1 2 Dimensions 6 1 3 Electrical Setup 6 2 INSTALLATION 7 2 1 Preliminary Checks 7 2 2 Installing the foundation box 7 2 3 Setting up the gate 7 2 4 Ins...

Страница 3: ...within line of sight of the gate Activation of the reset control shall not cause the operator to start 7 All warning signs and placards must be installed and easily seen within visible proximity of t...

Страница 4: ...stem component malfunctions disconnect the main power before attempting to repair it Do not impede the movement of the gate you may injure yourself or damage the gate system as a result This equipment...

Страница 5: ...loading docks or other locations not intended to service the general public RESTRICTED ACCESS VEHICULAR GATE OPERATOR CLASS IV A vehicular gate operator system intended for use in guarded industrial l...

Страница 6: ...in good condition Positivestopsareprovidedinthefullyopenedandclosed positions There is a minimum clearance between the bottom edge of gate and ground See Fig 6a where S thickness of guide bracket The...

Страница 7: ...Inches 2 2 Installing the foundation box 1 Dig a hole for the foundation box as shown in Fig 5 2 Place the foundation box in the hole refer to the dimen sions provided in Figs 6a and 6b The center of...

Страница 8: ...quired by repeating the operations described above 5 Install the electronic control unit Refer to the relative instructions 6 Fasten the box cover using the supplied screws Fig 14 Determine the correc...

Страница 9: ...out Fig 16 Ref 4 6 Operate the leaf manually Fig 17 At regular intervals check the structure of the gate and make sure that the hinges are in perfect working order Periodically lubricate the pivot an...

Страница 10: ...escription 1 770770 770 24V Motor 2 716078 Gear Box 3 727158 Gear Box Cover 4 718075 Secondary Shaft 5 718076 Internal Shaft Group 6 719165 Slow Shaft 7 390451 Seal Kit 8 63000452 Cap 9 63000590 V Rin...

Страница 11: ...2 3 4 5 6 6 Part Part Number Description 1 63000422 Release Levers Kit With Locks 2 63003015 Steel Ball 3 7271985 Cover Plug 4 727157 Box Cover 5 390477 Articulated Lever 6 424010 Manual Release Asse...

Страница 12: ...rs dipswitches and pushbutton RADIO Connector for the radio receiver BATTERY Connector for the backup battery J24 Jumper to disable battery charging With the jumper present the battery charger is enab...

Страница 13: ...closing safety 5 FSW OP N C Contact for opening safety 6 GND 24 Vdc negative 7 GND 24 Vdc negative 8 24 24 Vdc positive 9 OUT 24 Vdc negative for safety TX photocell monitored 10 FCA 1 Open limit swit...

Страница 14: ...between the opening leaves and fixed obstacles walls etc against the risk of entrapment Closing Safety Devices Are active only during the gate closing movement and are suitable for protecting the clo...

Страница 15: ...ing and closing areas against the risk of impact Typically these photocells work in combination with other monitored photocell pro tecting closing or opening entrapment zones In that case they can t b...

Страница 16: ...one closes During the mo vement a command stops the gate AP Automatic step by step OFF ON ON 0 4 min One command opens waits for the pause time and then closes automatically A command during the pause...

Страница 17: ...USE TIME ADJUSTMENT 0 4 min Turn clockwise to increase the pause time TR6 CLOSING DELAY OF LEAF 1 OVER LEAF 2 ADJUSTMENT 0 15 sec Turn clockwise to increase the delay TR1 FORCE ADJUSTMENT MOTOR 1 Turn...

Страница 18: ...lt OFF reverse when cleared ON SHADOW LOOP CONFIGURATION SW 9 Selects the behavior of the shadow loop function of the XIB accessory OFF The shadow loop input is active only before a closing command ig...

Страница 19: ...S450H S800H OFF OFF OFF S418 OFF OFF ON 415 390 770 ON OFF OFF DS 2 LOCK OUTPUT MODE OUTPUT MODE SW 4 Active only for 3 sec after an open impulse from gate closed OFF Active always except 3 sec befor...

Страница 20: ...EN B not active LED DL 16 STOP INPUT N C STOP non active STOP active or wiring error LED DL 17 FSW CL INPUT N C Closing safety devices clear Closing safety devices triggered or wiring error LED DL 18...

Страница 21: ...LED status If they are correct replace the encoder Verify motor and encoder wire gauge are correct Verify operator is not on manual and hydraulic units don t need to be bled 6 FAIL SAFE FAILED Verify...

Страница 22: ...7 32 17 15 32 The E024U board is supplied on a panel that fits in a 16x14 enclosure 6 3 OBSTACLE DETECTION FUNCTION 7 ENCLOSURE 1 Apply resistance to the gate and adjust the Force to make sure that th...

Страница 23: ...ollowing guidelines when installing the AC power 1 Check the local wiring codes in all cases and follow all local building codes Wiring and hookup should be performed by a qualified electrician instal...

Страница 24: ...rd could be damaged The E024U board keeps the operating firmware in a field pro grammable memory it can be easily upgraded through the on board USB port 10 FIRMWARE UPGRADE The E024U board allows the...

Страница 25: ...t release OPEN stops saves CLOSE OPEN recloses leaves immediately 1 recloses leaves immediately no effect OPEN CLOSE disabled no effect no effect CLOSE disabled no effect OPEN CLOSE disabled CLOSING r...

Страница 26: ...LOSE disabled recharges pause time CLOSE disabled CLOSING reopens leaves immediately reopens leaves immediately stops operation no effect reverses at opening see DS1 SW8 stops and opens at release OPE...

Страница 27: ...disabled no effect OPEN disabled no effect CLOSE disabled no effect OPEN CLOSE disabled LOGIC C CONTINUOS COMMANDS PULSES SYSTEM STATUS OPEN A OPEN B STOP FSW OP FSW CL FSW CL OP CLOSED opens the lea...

Страница 28: ...d to J2 7 Refer to Fig A11 for the wiring schematic 8 Turn power back ON 9 Press and release the SW1 button quickly The board will recognize that the XIB board has been removed 10 Re program run time...

Страница 29: ...ion Error condition on the BUS DL2 XIB board malfunction or no power J3 CL terminal open loop detector active or not connected J3 CL terminal closed loop detector in idle condition CL OP BUS BUS BUS N...

Страница 30: ...ERSE OPEN LED Turn the power on on the E024U board The LED on the inter face board will blink briefly and then will stay ON solid if the BUS connection is working correctly IMPORTANT Briefly press the...

Страница 31: ...been subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than o...

Страница 32: ...2016 FAAC International Inc All Rights Reserved Published in Sept 2016...

Отзывы: