34
ERn Wall-mount Installation Manual
Connect CAT5e Wiring
1:
Pull your CAT5e building wire through the conduit access previously prepared.
2:
The punch down connector provides insulation displacement therefore stripping of wire is not
required. Reference the connector label for the color code for Cat5e wire using the 568B
standard.
3:
Install the protective covers over the wire terminals.
4:
Install the punch down connector on the patch panel.
5:
Connect Ethernet patch cables.
a: Connect a patch cable from the left I/O to the first RJ-45 input on the Ethernet Switch panel.
b: Connect a patch cable from the punch down connector to an RJ-45 input on the switch
panel. Repeat for each building service connection (up to four).
6:
Install the Ethernet Switch Module into the enclosure and secure it in place using the captured
screws provided.
Note:
All Ethernet terminations must follow IEEE 802.3 and be terminated to the T568B
standard.
Note:
Use a 110 punch down tool to complete the wire termination.
As needed, press here gently with
screwdriver to release connector
from panel.