Configuration Settings (nn.cf)

Memory

Station Type (st)

The station's software is capable of mimicking several ETC standard button and fader 
station types. However changing the type from its default (12 button, 16 Fader station 
type) has its disadvantages, most notable of them are a reduced number of buttons and 
faders. Most users will make the best use of this station as its default type and will not 
need to make use of this feature. This always yields the highest quantity of controllable 
items even if they are left unused. The 12 button, 16 fader station type is also the only type 
allowed when Emphasis mode is enabled (see 

With Emphasis [Serial Button Protocol] on 

page 2

).

This property sets the type of station that the AV/Serial Interface station will emulate. 
Although there is nothing preventing you from setting this property to any value, only the 
ones listed below will be recognizable by a Unison processor.

(nn) Index

Settings (cf)

1

Echo

0 = off

, 1 = on

2

No update

0 = off

, 1 = station will be polled by the computer

3

Level & fader scale

0 = 0-255

, 1 = 0-100

4

Reply terminator

0 = CRLF

, 1 = CR (LF is always ignored on 

receiving)

5

Packet mode

0 = disabled

, 1 = enabled

6

Emphasis mode

0 = disabled

, 1 = enabled

7

Configuration jumpers

Values of 4 configuration bits. Only bit 0 has 
jumper pins on the PCB.

99

Reset station

1 = set configuration to defaults, clear memories, 
set fade rates to 0, set key and fader LEDs to off, 
set levels to 0, and clear bindings.

Notes:

• Configuration switches are stored in EEROM and are retained during a 

power loss.

• When packet mode is enabled, commands are prefixed with a one-byte 

preamble. The eighth bit (MSB) is always a logical one and the lower 
7 bits should contain the number of bytes in the command. The length 
should only be calculated for the command and does not include the 
preamble or the terminator. Valid commands are replied with an ACK 
command. Invalid commands are replied with a NAK command. 
Packet mode cannot be enabled until Echo is turned off.

• Configuration jumper settings: J2-B enables Emphasis mode.
• Emphasis mode only affects outgoing messages (station to host).

nn

Index

Settings

1

Fader levels

0 = clear

, 1 = save

2

Fader rates

0 = clear

, 1 = save

3

Button states

0 = clear

, 1 = save

Notes:

• Get Memory returns 1 if any item saved is in a non-default state.

Содержание Unison AV/Serial Interface v1.0.0

Страница 1: ...visual feedback LEDs on a standard wall station The functionality of the AV Serial Interface station in a Unison system is easily configured by adding a new station the default type is the 12 button...

Страница 2: ...ment is still accepted from host to station to allow any reconfiguration of the station The Unison Light Manager configuration must be configured with the12 button 16 fader station type as enabling Em...

Страница 3: ...eive data RX pin 5 Common Com port settings are 9600 baud 8 bits no parity 1 stop bit and Xon Xoff flow control Station Configuration with a Computer Example Connect your computer to the station with...

Страница 4: ...U Update An automatic system response initiated by a status change of an item on the station such as a button s LED turning on L Level M Memory R Rate S Status T Type V Version Object Get Command Get...

Страница 5: ...10 installed but unbound 0x0020 installed bound Bit Description 0 Station reset occurred 1 Station wink occurred 2 A command error occurred 3 UART error occurred 4 5 Unison install status 00 unistalle...

Страница 6: ...2 No update 0 off 1 station will be polled by the computer 3 Level fader scale 0 0 255 1 0 100 4 Reply terminator 0 CRLF 1 CR LF is always ignored on receiving 5 Packet mode 0 disabled 1 enabled 6 Emp...

Страница 7: ...That clears all bindings for the station Station ID Station Description 100 5 buttons 200 10 buttons 800 12 buttons 4 faders 900 12 buttons 7 faders 1000 12 buttons 10 faders 1200 12 buttons 13 faders...

Страница 8: ...SF0 only clears all faders SR0 only clears all rates SB0 only clears all buttons The Escape command clears bindings takes station to disconnected state and sends a service pin message The Help command...

Страница 9: ...ype the preamble character by holding the Alt key while typing the 4 digit number listed while using a terminal emulator such as Hyper Terminal You will see the display character if you have local ech...

Отзывы: