System Power Up and Configuration
24
Fuse Replacement
Replace Input Power Fuse
The input power circuit is protected from overload and short circuits by a user replaceable
fuse.
• Replace the One-Zone LV Power Supply input fuse with a 5 x 20mm 1.25A, 250V time delay fuse.
• Replace the Six-Zone LV Power Supply input fuse with a 5 x 20mm 3A, 250V time delay fuse.
Replace Outputs Fuse
All outputs are protected from
overload and short circuits by a user
replaceable fuse.
• Replace the One-Zone LV Power
Supply output fuse with a 1.6A,
250V fuse.
• Replace the Six-Zone LV Power Supply
output fuse with a 1.25A, 250V fuse.
WARNING:
RISK OF DEATH BY ELECTRIC SHOCK! Failure to disconnect all power
to the system before installation, maintenance, cleaning or any other
system modification, could result in serious injury or death.