System Installation
18
Terminate Remote Switch Wiring
One-Zone LV Power Supply
Step 1:
Insert the wire from one side of the dry contact into terminal 1 and tighten the screw
firmly onto the wire.
Step 2:
Insert the wire from the other side of the dry contact into terminal 2 and tighten the
screw firmly onto the wire.
Six-Zone LV Power Supply
Step 1:
Remove the connector from the unit.
Step 2:
Insert the wire from one side of the dry contact into the removable connector at Ch.1
and tighten the screw firmly onto the wire.
Step 3:
Insert the wire from the other side of the dry contact into the removable connector at
COM and tighten the screw firmly onto the wire.
Step 4:
Repeat Steps 1-2 for all of the dry contacts.
Step 5:
Install the connector into the unit.
Note:
Switched connection requires a dry contact such as a switch or relay. Wires with
voltage present should not be landed here.