7.6 Electrical Installation
Installation of electrical components can be performed by a competent person, but the installation
needs to be supervised by a qualified person.
7.6.1 Mains Connection
Vortek hoist mains power input requires a 3-phase+Earth [ground connection to the Motor
Control Box (MCB) power supply].
400VAC, 3P+N+PE, 50Hz
The power supply to the Vortek hoist must be protected by an external fuse or circuit breaker with
rating not exceeding 16A.
The wires in the supplied mains input connection cable are colour-coded as follows:
• Phase L1 - Brown
• Phase L2 - Black
• Phase L3 - Grey or Black
• Neutral - Blue
• Earth (ground) - Yellow/Green
WARNING:
Confirm the number of crimps required for the Nicopress sleeve by reviewing
the Nicopress crimp tool manual.
WARNING:
Do not connect the Vortek hoist electrical connection to any power supply
socket that has not been tested by a qualified individual.