ETC ArcSystem Pro One-Cell Скачать руководство пользователя страница 6

ETC Installation Guide

Pro One-Cell

Pro One-Cell

Page 6 of 29

ETC

Before You Begin Installation

Review the following sections before beginning your ArcSystem installation. ArcSystem products
should only be installed by a qualified installer or electrician.

Power Disconnect Device

Before installation, make sure you have a readily accessible input power disconnect device installed
ahead of your ArcSystem products.

WARNING:

RISK OF DEATH BY ELECTRIC SHOCK! Failure to disconnect all

power to the system before installation, maintenance, cleaning, or any other
system modification could result in serious injury or death.

AVERTISSEMENT :

RISQUE DE MORT PAR DÉCHARGE ÉLECTRIQUE! Négliger

de débrancher toutes les sources d’alimentation du système avant l’installation,
l’entretien, le nettoyage ou toute autre modification du système peut causer
des blessures graves ou la mort.

De-energize main feed to ArcSystem and follow appropriate Lockout/Tagout
procedures as mandated by NFPA 70E. It is important to note that electrical
equipment such as breaker panels can present an arc flash hazard if improperly
serviced. This is due to the high amounts of short-circuit current available on
the electrical supply to this equipment. Any work must comply with OSHA Safe
Working Practices.

WARNING:

Circuits that are installed without an accessible power disconnect

device cannot be serviced or operated safely.

AVERTISSEMENT :

Il est imprudent d'utiliser ou de réparer les circuits

installés sans qu'un dispositif de déconnexion de l'alimentation ne soit
accessible.

Site Survey for Wireless Installations

ArcSystem transmitters and luminaires operate in the unlicensed 2.4 GHz band using the IEEE
802.15.4 standard. This band is shared with other technologies such as Wi-Fi, Bluetooth, low power
sensor networks, wireless AV transmitters and some radio microphones.

Before commissioning a system, a wireless site survey is essential.

Gathering information on how your wireless lighting system will overlap with all other Wi-Fi traffic in
the area will help determine setup of transmitters and which luminaires should be re-broadcasting,
not just receiving wireless data.

Installation Requirements

Indoor installation only: 0–40°C (32–104°F), 5–95% non-condensing humidity.

Dry locations only.

Installation location must support the weight of the luminaire, driver, and applicable mounting
hardware.

CAUTION:

ArcSystem luminaires and drivers are not suitable for use in spaces

with restricted air flow. Enclosing the luminaires or drivers temporarily or
permanently may cause damage to the luminaires or drivers.

Содержание ArcSystem Pro One-Cell

Страница 1: ...ystem products with ArcMesh can be controlled using wired DMX or the wireless ArcMesh protocol ArcSystem products without ArcMesh can be configured for RDM control This manual provides step by step in...

Страница 2: ...ount with single axis tilt yoke mount version with single axis tilt beam angle options 19 24 37 60 ArcSystem Pro One Cell High Output external 100 277 V D1 HO driver required ideal for long throw 100...

Страница 3: ...One Cell Small luminaire The D1 HO Driver provides up to 100 W to a single One Cell High Output luminaire The D2 Driver supports one or two One Cell Micro luminaires and provides up to 10 W per outpu...

Страница 4: ...s can be configured to be UL924 listed when wired into an existing emergency response system See Emergency System One Cell Installation on page 19 Install the ArcSystem D1 D2 or D4 Series driver in a...

Страница 5: ...NING Do not mix 120 V and 277 V between the sense and emergency feeds AVERTISSEMENT Ne pas inverser les alimentations 120 V et 277 V entre les alimentations de d tection et de secours WARNING Sense no...

Страница 6: ...al supply to this equipment Any work must comply with OSHA Safe Working Practices WARNING Circuits that are installed without an accessible power disconnect device cannot be serviced or operated safel...

Страница 7: ...ne Cell Micro luminaires The D4 driver can control up to four ArcSystem Pro One Cell or Pro One Cell Small luminaires Up to 32 drivers can be installed on one hard wired line of DMX The following illu...

Страница 8: ...ps screwdriver Four 10 screws and other mounting hardware as needed Note Mounting hardware and installation location must support the weight of the driver conduit hardware and all cable required for i...

Страница 9: ...5 Nm 3 5 4 4 in lb Note Maximum supported wire length between One Cell luminaires and D1 Series and D2 Series drivers is 15 m 49 ft Maximum supported wire length between any load and a D4 Series drive...

Страница 10: ...can extend through the ceiling opening so that the driver and luminaire can be inspected and serviced when needed Note Use suitable conduit where required by national and local codes Note Drivers may...

Страница 11: ...One Cell luminaires Luminaire Minimum Hole Diameter Pro One Cell 16 5 cm 6 1 2 in Pro One Cell High Output 17 0 cm 6 11 16 in Pro One Cell Small 9 5 cm 3 3 4 in Pro One Cell Micro 7 6 cm 3 in Note If...

Страница 12: ...inaire Wiring of the driver consists of wiring power and data DMX to the driver for your luminaire and then running power out to the luminaire from the driver If you are installing emergency system dr...

Страница 13: ...One Cell Page 13 of 29 ETC Output type varies by model A B C S1 S2 S3 S4 LED1 LED2 LED3 LED4 Switch blocks D4 Driver A Constant Current with Molex connectors B Constant Current with terminal outputs C...

Страница 14: ...ou de r parer les circuits install s sans qu un dispositif de d connexion de l alimentation ne soit accessible 1 Make sure power is off at the main circuit breaker 2 See Wire and Terminal Specificati...

Страница 15: ...10 m 33 ft 1 Install the ceiling with the prepared mounting hole for the luminaire 2 Run the luminaire cable through the previously installed screw clamp conduit connector at one of the driver knockou...

Страница 16: ...and Data plus an ISO ground common ETC recommends Cat5e or better minimum 24 AWG conductors terminated to T568B standard Up to 32 D1 D2 or D4 series drivers can be connected per DMX run DMX Connectio...

Страница 17: ...tage CV model driver Switch 1 sets the current output threshold ON 400 mA OFF 600 mA Switches 2 through 5 control the DMX channel assigned to the output Switch 6 enables emergency functionality Switch...

Страница 18: ...DU DRIVER DISPOSITIF LECTRONIQUE DE PUISSANCE WARNING Adjustable ArcSystem Pro One Cell fixtures and adjustable ArcSystem Pro One Cell Small fixtures are suitable for Non Fire Rated installations ONLY...

Страница 19: ...s those of the standard ArcSystem Complete the installation as follows referencing the following sections for any additional installation details before wiring the power Preparing to Install the Drive...

Страница 20: ...ge 20 of 29 ETC Output type varies by model A B C S1 S2 S3 S4 LED1 LED2 LED3 LED4 Switch blocks SENSE SENSE D4 Emergency Driver A Constant Current with Molex connectors B Constant Current with termina...

Страница 21: ...ND terminal and tighten the screw 4 Insert the neutral wire typically white into the NEUTRAL N terminal and tighten the screw 5 Connect the line wire typically black into the LINE L terminal and tight...

Страница 22: ...o not change the switch 1 settings on a D4 Constant Voltage CV model driver Switch 1 sets the current output threshold ON 400 mA OFF 600 mA Switches 2 through 5 control the DMX channel assigned to the...

Страница 23: ...or normal use During normal use after commissioning is complete ArcSystem luminaires will light if the DMX Control level is greater than 0 DMX System Control ArcSystem with ArcMesh can be installed an...

Страница 24: ...es RDM Values Manufacturer ID 0x6574 Electronic Theatre Controls Model IDs Product Type Description Model ID ArcSystem Pro One Cell or ArcSystem Pro One Cell Small D1 Driver 0x1201 D1 Emergency Driver...

Страница 25: ...steps 0x04 700 ms 70 steps 0x05 600 ms 60 steps 0x06 500 ms 50 steps 0x07 400 ms 40 steps 0x08 300 ms 30 steps 0x09 250 ms 25 steps 0x0A 200 ms 20 steps 0x0B 100 ms 10 steps 0x0C 50 ms 5 steps 0x0D 0...

Страница 26: ...avant d effectuer un nettoyage ou un entretien WARNING Circuits that are installed without an accessible power disconnect device cannot be serviced or operated safely AVERTISSEMENT Il est imprudent d...

Страница 27: ...tion du syst me peut causer des blessures graves ou la mort De energize main feed to ArcSystem and follow appropriate Lockout Tagout procedures as mandated by NFPA 70E It is important to note that ele...

Страница 28: ...ance ARCPD1DM ArcSystem D1 Driver cULus Conforms to UL 8750 Certified to CSA C22 2 No 250 13 EU CE Certified FCC compliant ARCPD1DRDMM ArcSystem D1 RDM Driver ARCPD1HDM ArcSystem D1 High Output Driver...

Страница 29: ...cy Driver with Two Pin Terminals ARCPED4DCVTM ArcSystem D4 Constant Voltage Emergency Driver with Two Pin Terminals ARCPED4DCVTRDMM ArcSystem D4 Constant Voltage Emergency Driver with Two Pin Terminal...

Отзывы: