ETC Installation Guide
Pro One-Cell
Pro One-Cell
Page 25 of 29
ETC
Parameter
RDM PID
Value
Notes
DMX Start Address
0x00F0
Range = 001 to 512
Default is 001. The upper limit for the D4 Series
drivers is 508.
DMX Personality
0x00E0
1 or 2
Default is 2. This parameter sets the number of
DMX channels available on a D4 Series driver.
•
Set to 1 sets DMX personality to multi-channel.
•
Set to 2 sets DMX personality to single-
channel.
Identify Device
0x1000
0 for stop identify, 1 for start
identify
Set to 1 causes output(s) and LEDs of the unit to
blink in a one second on, one second off pattern.
Minimum Level
0x0341
0 to 255
Default is 99%. The luminaire will not accept a
Minimum Level that is higher than the Maximum
Level.
Maximum Level
0x0342
0 to 255
Default is 100%. The luminaire will not accept a
Maximum Level that is lower than the Minimum
Level.
Curve
0x0343
1, 2, or 3
•
Set to 1 is the Default Tungsten Curve (aka
D04A)
•
Set to 2 is Linear
•
Set to 3 is Square Law
Curve Description
0x0344
Get returns an ASCII text string.
Output Response Time
0x0345
•
0x01 1000 ms/100 steps
•
0x02 900 ms/90 steps
•
0x03 800 ms/80 steps
•
0x04 700 ms/70 steps
•
0x05 600 ms/60 steps
•
0x06 500 ms/50 steps
•
0x07 400 ms/40 steps
•
0x08 300 ms/30 steps
•
0x09 250 ms/25 steps
•
0x0A 200 ms/20 steps
•
0x0B 100 ms/10 steps
•
0x0C 50 ms/5 steps
•
0x0D 0 ms/0 steps
Default is 500ms/50 steps. This parameter
controls dimming up in level.
Output Response Time
Down
0x8030
Default is 500 ms/50 steps. This parameter
controls dimming down in level. Set 0x00 to set
the Output Response Time Down to the same
setting as Output Response Time.
Output Response Time
Description
0x0346
Get returns an ASCII text string.
Modulation Frequency
0x0347
32-bit unsigned integer
representation of the frequency
in Hz
•
300 for 300 Hz
•
600 for 600 Hz
•
1200 for 1.2 kHz
•
19200 for 19.2 kHz
Default is 300 Hz.
Modulation Frequency
Description
0x0348
Get returns an ASCII text string.
Restore Factory Defaults
0x0090
Set resets the luminaire configuration to default
settings.
Software Version Label
0x00C0
Get returns the current software version as an
ASCII text string.
Bootloader Version Label
0x00C2
Get returns the current bootloader version as an
ASCII text string.
Updating the Luminaire Software
ETC recommends using UpdaterAtor software to manage software updates. For more information on
UpdaterAtor, download the
UpdaterAtor Software Quick Guide
for free from
.