ETAS
Installation
FETK-T3.0 - User’s Guide
36
5.2
Connection to the ECU
5.2.1
FETK-T3.0 Adapters
For connecting the FETK-T3.0 to the ECU two FETK adapter cables are recom-
mended:
• at CON1 adapter cable ETAN2 or ETAN8
• at CON2 adapter cable ETAM2 or ETAM5 or ETAM9 or ETV5
For additional details to connect the FETK-T3.0 to the ECU with adapter cables
see Fig. 5-6. The adapter cables can be ordered separately (refer chapter
“Ordering Information” on page 87).
Fig. 5-5
FETK-T3.0 Connection to the ECU
CAUTION
Risk of short circuiting the internal signals of the FETK!
When you mount the FETK to the ECU, you must ensure that the screws and
washers used will not penetrate the FETK printed circuit board.
ETA N2/ 8
ETA M 2/ 5/ 9
or
ETV5
FETK-T3.0