ETAS
Technical Data
FETK-T3.0 - User’s Guide
48
7.4
Power Supply
Parameter
Symbol
Condition
Min
Typ
Max Unit
Permanent power
supply
U
Batt
Vehicle usage
1)
6.0
12
36
V
[all /-0%]
Cranking voltage U
Batt
< 3 seconds
3
V
Deep standby
current
I
STBY1
U
Batt
= 12 V;
ECU off;
no load from ECU;
T = 20 °C
1
3
5
mA
Standby current
I
STBY2
U
Batt
= 12 V;
ECU off;
no load from ECU;
T = 20 °C
50
78
110
mA
Operating current I
Batt
U
Batt
= 12 V;
no load from ECU;
T = 20 °C
230
330
420
mA
Power dissipation P
Batt
U
Batt
= 12 V;
I = 0 mA at pin
ECU_SBRAM;
T = 20 °C
2.76 3.96 5.04 W
Power consump-
tion on FETK-T3.0
P
Batt
U
Batt
= 12 V;
I = 500 mA at pin
VDDSTBY [1.25 V];
I = 80 mA at pin
VDDPSTBY;
T = 20 °C
3.86 5.06 6.14 W
1)
The FETK-T3.0 implements reverse voltage protection in the same range
and may be used only with central load dump protection.
24 V vehicles require U
Batt
disturbing pulse reduction to 12 V vehicle system.
12 V vehicles don’t require special disturbing pulse reductions.
NOTE
The values above are not including the power dissipation of the microcontrol-
ler EMU RAM part.
NOTE
The FETK-T3.0 will accept permanent power supply voltage dips (for addi-
tional details of 3 V low voltage operation, see ISO standard 16750).