Technical Data
6.8
Electrical Data
6.8.1
Voltage Supply
Operating voltage
4.75 V to 5.25 V DC
Supply via the USB port (see chapter
6.7.1 on page 37)
Current consumption, max. (during
operation)
350 mA at 5.0 V DC
6.8.2
CAN Interface
CAN
One interface,
isolated from the USB port,
each channel can be configured sepa-
rately
Standard
ISO 11898-1, ISO 15765-4,
ISO 11898-2:2015
Protocols
CAN V2.0a (standard identifier),
CAN V2.0b (extended identifier)
CAN FD
(ISO/CD 11898-1:2015; Bosch CAN FD
specification V1.0 [non-ISO])
Transmission speed
High-speed CAN/CAN FD header:
Max. 1 MBaud for 20 m bus length
CAN FD (data): Max. 5 Mbit/s (operat-
ing temperature range)
CAN FD (data): Max. 8 Mbit/s (room
temperature)
CAN interface clients
Max. 2
Controller
ARM Cortex MCU
Transceiver (physical layer)
TJA1044G