background image

ES584.1 – User’s Guide

9

ETAS

Basic Safety Notices

2

Basic Safety Notices

This chapter contains information about the following topics:

• "General Safety Information" on page 9,
• "Requirements for Users and Duties for Operators" on page 9,
• "Intended Use" on page 9.

2.1

General Safety Information

Please observe the product safety information ("ETAS Safety Advice") and the 
following safety instructions to avoid health hazards or damage to the device. 

Read the documentation supplied with the product (Product Safety Advice and 
this user manual) prior to starting up the product.

ETAS GmbH does not assume any liability for damage due to improper handling, 
improper use or non-compliance with safety measures.

2.2

Requirements for Users and Duties for Operators

The product may be assembled, operated and maintained only if you have the 
required qualification and experience for this product. Improper use or use by a 
user without sufficient qualification can put life at risk or cause damage to health 
or property.

The system integrator is responsible for the safety of systems that use the prod-
uct.

General safety at work

The existing regulations for safety at work and accident prevention must be fol-
lowed. All applicable regulations and laws regarding operation must be strictly 
adhered to when using this product.

2.3

Intended Use

Application area of the product

This product was developed and approved for applications in the automotive 
sector. The module is suitable for use in interiors, in the passenger compartment 
or in the trunk of vehicles. The module is not suitable for installation in the 
engine compartment and similar environments.

 

For use in other application 

areas, please contact your ETAS contact partner.

Requirements for the technical state of the product

The product is designed in accordance with state-of-the-art technology and rec-
ognized safety rules. The product may be operated only in a technically flawless 
condition and according to the intended purpose and with regard to safety and 
dangers as stated in the respective product documentation. If the product is not 
used according to its intended purpose, the protection of the product may be 
impaired.

Note

Содержание ES584.1

Страница 1: ...ES584 1 CAN FD and LIN Bus Interface USB Module User s Guide...

Страница 2: ...single license Using and copying is only allowed in concurrence with the specifications stipulated in the contract Under no circumstances may any part of this document be copied reproduced transmitte...

Страница 3: ...uties for Operators 9 2 3 Intended Use 9 3 Hardware Description 13 3 1 Overview 13 3 2 Application Areas 14 3 3 Properties 15 3 4 Function Groups 16 3 5 CAN FD Interface 16 3 5 1 Operating Modes 16 3...

Страница 4: ...Displays of the LEDs 31 5 2 Problems with the ES584 1 31 6 Technical Data 33 6 1 General Data 33 6 1 1 Labeling on the Product 33 6 1 2 Standards 34 6 1 3 Ambient Conditions 34 6 1 4 Maintenance of th...

Страница 5: ...ES584 1 User s Guide 5 ETAS Contents 8 Order Information 49 8 1 ES584 1 CAN FD and LIN Bus Interface USB Module 49 8 2 Accessories 49 9 ETAS Contact Addresses 51 Figures 53 Index 55...

Страница 6: ...ES584 1 User s Guide 6 ETAS Contents...

Страница 7: ...al are marked with the general danger symbol shown below The safety notices shown below are used alongside this symbol They point out extremely important information Please read this information caref...

Страница 8: ...ons The following typographical conventions are used Bold Labels on the device Italic Particularly important text passages Important notes for the user are presented as follows Important note for the...

Страница 9: ...or property The system integrator is responsible for the safety of systems that use the prod uct General safety at work The existing regulations for safety at work and accident prevention must be fol...

Страница 10: ...le Ensure that the connection and setting values are adhered to see the information in the chapter Technical Data Do not apply any voltages to the connections of the module that do not correspond to t...

Страница 11: ...the module or the module stack on a smooth level and solid sur face Requirements for the ventilation Keep the module away from heat sources and protect it against direct exposure to the sun Transport...

Страница 12: ...the pro tection class Do not open or change the module housing Work on the module housing may only be performed by ETAS CAUTION Potential equalization in the vehicle is possible via the shield of the...

Страница 13: ...n page 20 Multi Client Support on page 21 Updating the Firmware on page 21 3 1 Overview The ES584 1 CAN FD and LIN Bus Interface USB Module is part of the range of compact ETAS bus interface modules I...

Страница 14: ...y INCA such as CCP XCP KWP on CAN and UDS The CCP and KWP on CAN ISO 14230 ISO 15765 protocols are only supported in classic CAN mode The costs for installation and configuration of the affordable mod...

Страница 15: ...client access to the same CAN channel Max two clients can access the device Two clients per channel DSUB connector in accordance with CAN in Automation CiA One LIN interface Simple and direct connecti...

Страница 16: ...interface CAN on its nine pin DSUB socket The CAN interface is an independent CAN channel with its own CAN controller It is isolated from the USB port of the ES584 1 3 5 1 Operating Modes The CAN inte...

Страница 17: ...to set up CAN net works Some CAN networks are already terminated for example in a vehicle so no additional termination is required 3 5 5 Minimum Requirements for the CAN Connection At least the follow...

Страница 18: ...r 6 7 2 on page 39 3 6 3 Voltage Supply on the LIN Bus LIN_GND 9 3 7 LIN LIN_UBATT DSUB 9 Fig 3 3 Voltage supply on the LIN bus pin assignment on the CBCF100 cable 12 V LIN systems In 12 V LIN systems...

Страница 19: ...switchable internal voltage source of the module This internal supply voltage is not routed outside via the CAN LIN plug connec tor 3 7 USB Port The module is permanently connected using a cable with...

Страница 20: ...on on the CAN interface inter rupted Red Communication error on the CAN interface BUSY Blue The module is currently in the boot phase or a firmware update is being performed Do not disconnect the modu...

Страница 21: ...e possible using an application tool e g INCA and a bus analysis tool e g BUSMASTER In total each ES584 1 module connected to the PC can serve four different clients or application tools 3 12 Updating...

Страница 22: ...ES584 1 User s Guide 22 ETAS Hardware Description...

Страница 23: ...n dows 7 Windows 8 and Windows 10 Following installation of the driver you can use remove the ES584 1 module at any time 4 2 Preparing to Install 4 2 1 Checking the System Requirements Check whether y...

Страница 24: ...river is identical whether using the DVD or a network drive Installing the USB driver for the ES584 1 Insert the DVD into your PC In the main window of the DVD select the Drivers option The Drivers wi...

Страница 25: ...ES584 1 User s Guide 25 ETAS Commissioning Read and accept the end user license agreement Click on Next The installation of the USB driver starts Wait until the USB driver is installed...

Страница 26: ...ES584 1 User s Guide 26 ETAS Commissioning Click on Exit The installation of the USB driver for the ES584 1 is then complete...

Страница 27: ...USB port on the PC or drive recorder Select Start Control Panel Device Man ager The Device Manager window opens Select ETAS Bus Interfaces Check whether the new entry ES584 1 is displayed for the ES58...

Страница 28: ...ays an information note in the start bar In Fig 4 2 on page 28 you can see an image of the information notes that appear Fig 4 2 Windows information note 4 6 Updating the USB Driver The ES584 1 update...

Страница 29: ...r for the ES584 1 Disconnect the ES584 1 module from the USB port on the PC or drive recorder Select Start Control Panel Programs and Features The Programs and Features window appears Select the entry...

Страница 30: ...e USB driver starts Wait until the USB driver is uninstalled Click on Exit The uninstallation of the USB driver for the ES584 1 is then complete 4 8 J2534 Driver Installation of a J2534 driver is not...

Страница 31: ...ell as their correspond ing solutions If you have any further questions please contact our technical ser vice see chapter 9 on page 51 Problem Diagnostics questions Possible solution The computer does...

Страница 32: ...the module Check with HSP whether the required firmware is installed on the module Is the hardware connected to the PC Check whether the cabling is intact The measurements are not being started Does t...

Страница 33: ...minal Assignment on page 42 6 1 General Data 6 1 1 Labeling on the Product The following symbols are used to label the product Symbol Description Read the user manual before starting up the product SN...

Страница 34: ...40 C to 70 C 40 F to 158 F Temperature range in storage 40 C to 85 C 40 F to 185 F Relative humidity non condensing 15 to 95 during operation 0 to 95 in storage Operating altitude Max 5000 m 16 400 ft...

Страница 35: ...nt WEEE to ensure the setup of systems for collecting treating and recycling electronic waste in all countries of the EU This ensures that the devices are recycled in a resource friendly way that does...

Страница 36: ...using dimensions H x W x D 24 mm x 48 mm x 86 7 mm 0 8 x 1 6 x 2 52 Length of the integrated USB cable 1 5 m 4 9 ft Weight Approx 150 g 5 291 oz with USB cable Housing Nylon rubberized Connection on P...

Страница 37: ...whose USB interface meets the requirements stated in the table The use of USB cables to extend the connection between ES584 1 and the PC or drive recorder is not permitted The module does not support...

Страница 38: ...anagement in your application If you have strict time management requirements for your application time controlled transfer of messages time controlled evaluations you must deacti vate this power mana...

Страница 39: ...LINK 3 LIN monitoring MC 1 V11 6 0 V7 2 6 LIN 4 1 MC Measurement and calibration 2 MC DS ECU diagnostics 3 INCA V7 2 6 and higher also INCA add on ODX LINK V7 2 x and higher 4 INCA V7 2 6 and higher...

Страница 40: ...rt each channel can be configured sepa rately Standard ISO 11898 1 ISO 15765 4 ISO 11898 2 2015 Protocols CAN V2 0a standard identifier CAN V2 0b extended identifier CAN FD ISO CD 11898 1 2015 Bosch C...

Страница 41: ...ernal from the LIN bus LIN VBAT external 12 V LIN systems 8 V to 18 V 24 V LIN systems 16 V to 36 V Operating modes Master or slave can be selected in the application soft ware 2 LIN interface clients...

Страница 42: ...N FD and LIN Bus Interface USB Module via the nine pin DSUB connector see Fig 6 3 5 1 9 6 Fig 6 3 ES584 1 DSUB connector Pin Signal Meaning 1 N C Not connected 2 CAN Low CAN Low 3 GND 1 Ground 1 4 N C...

Страница 43: ...7 9 3 2 5 7 9 Shell 6 6 Shell Shell Plug A Plug 1 Plug 2 Fig 7 3 CBCF100 cable wiring diagram Assigning DSUB connectors 1 and 2 of the CBCF100 cable to the ES584 1 If a CBCF100 cable is used at the C...

Страница 44: ...onnection DSUB connector 1 CAN Pin Signal Pin Signal 1 N C 1 DSUB socket pin 1 2 CAN Low 2 CAN Low 3 GND 3 GND 4 N C 4 N C 5 N C 5 N C 6 GND 6 GND 7 CAN High 7 CAN High 8 LIN 8 N C 9 LIN VBAT 9 LIN VB...

Страница 45: ...te Pin Pin 7 6 CAN High CAN High and CAN Low in a shielded twisted pair 2 14 CAN Low CAN High and CAN Low in a shielded twisted pair 8 3 LIN LIN and LIN GND in a shielded twisted pair 4 11 LIN GND LIN...

Страница 46: ...annel Order designation Short name Order number CAN LIN and FlexRay interface cable DSUB DSUB 9fc 9mc 9fc 2 m CBH500 2 F 00K 106 276 7 4 CBCX130 Cable FMH1 CBCX130 1 2 F 00K 103 784 CAN FMH1 Fig 7 6 C...

Страница 47: ...31 1 0 Adapter 5 4 3 2 1 6 7 8 9 5 4 3 2 1 9 8 7 6 120 Ohm Fig 7 7 CBCX131 1 0 terminating resistor CAN 120 ohm terminating resistor 2xDSUB 9fc 9mc Order designation Short name Order number CAN 120 oh...

Страница 48: ...ES584 1 User s Guide 48 ETAS Cables and Accessories...

Страница 49: ...of this Package list ES58x_ETAS_Safety_Advice China RoHS leaflet_Com pact_green_cn 8 2 Accessories Order name Short name Order number CAN and FlexRay interface Y cable DSUB 2 x DSUB 9fc 9mc 9mc 0m3 CB...

Страница 50: ...ES584 1 User s Guide 50 ETAS Order Information...

Страница 51: ...tuttgart Fax 49 711 3423 2106 Germany WWW www etas com ETAS Subsidiaries and Technical Support For details of your local sales office as well as your local technical support team and product hotlines...

Страница 52: ...ES584 1 User s Guide 52 ETAS ETAS Contact Addresses...

Страница 53: ...LEDs 20 Fig 4 1 Windows Device Manager 27 Fig 4 2 Windows information note 28 Fig 6 1 WEEE symbol 35 Fig 6 2 Dimensions 36 Fig 6 3 ES584 1 DSUB connector 42 Fig 7 1 CBCF100 cable 43 Fig 7 2 CBCF100 ca...

Страница 54: ...ES584 1 User s Guide 54 Figures ETAS...

Страница 55: ...FD Interface CAN 16 CAN Interface 40 CBCX131 1 0 Adapter 47 CD ROM 23 Cleaning 34 Commissioning 23 D Documentation 9 E Electrical safety 10 ES584 1 J2534 Driver 30 ETAS Contact Addresses 51 F Feature...

Страница 56: ...roduct return 35 Properties 15 Q Qualification required 9 R Recycling 35 S Safety at work 9 10 Safety notices basic 9 Marking 7 Safety precautions 9 Scope of Supply 8 Software Open Source 35 System re...

Отзывы: