ES5340.2 Electric Drive Simulation Board - User’s Guide
75
ETAS
Configuring the Hardware in LABCAR-RTC
Determining Default Values
For certain model inputs, default values can be defined in the "Data" tab.
5.2.2
Software Model
If a model is run on the Real-Time PC, an item must be added for measurement
of the inverter gate signals from the ECU; in addition, a map of the current/
voltage values to the analog outputs must be created.
The duty cycles and the period of the PWM control signals are measured and
forwarded to the software model. The measurement itself can be synchronized
to an external signal or to the PWM period determined by clock recovery.
Configuring the Inverter Gate Measurement
1. Right-click the "ES5340-Digital-In" item and select
Add Item
.
2. In the list, select the "ES5340-Dig-In-Inverter-Meas"
item and click
OK
.
The item is added.