ES5340.2 Electric Drive Simulation Board - User’s Guide
111
ETAS
Technical Data and Standards
8
Technical Data and Standards
8.1
Technical Data
Analog Outputs
Digital Outputs
Number on ES5340.2-M
8 (6 single-ended, 2 differential or single-ended
for resolver sensor)
Number on ES5340.1-S
6 (single-ended)
Output voltage range
-10 V to +10 V (internal reference)
-12 V to +12 V (external reference)
Accuracy without load
±5 mV (+23 °C/+73 °F)
Accuracy with load (12 k
Ω
)
±10 mV (+23 °C/+73 °F)
Output current
±30 mA (typical)
Resolution
16 bit
Overvoltage protection
±60 V
Galvanic isolation
Yes
Number on ES5340.2-M
8
Number on ES5340.1-S
6
Output voltage range
Open collector: 0 to 60 V
Internal pull-up: 5 V
Output current
Max. ±15 mA
Frequency range
1 Hz...100 kHz
Accuracy between 1 Hz and 10 kHz
±0.04%
Accuracy between 10 kHz and 100 kHz
±0.4%
Rise time (0 V
→
5 V)
2 μs (typical)
Fall time (5 V
→
0 V)
2 μs (typical)
Duty cycle
0%...100%
Accuracy duty cycle (50%) between 1 Hz and
10 kHz
±0.2%...±2% (linear)
Accuracy duty cycle (50%) between 10 kHz and
100 kHz
±2%...±20% (linear)
Clock rate for PWM generation
8 ns
Overvoltage protection
±60 V
Galvanic isolation
Yes
Max. number of SENT signals
4
SENT specification (version)
SAE J2716
Galvanic group SENT
One group with 4 channels
Содержание ES5340.2
Страница 1: ...ES5340 2 Electric Drive Simulation Board User s Guide...
Страница 6: ...ES5340 2 Electric Drive Simulation Board User s Guide 6 Contents ETAS...
Страница 22: ...ES5340 2 Electric Drive Simulation Board User s Guide 22 Introduction ETAS...
Страница 102: ...ES5340 2 Electric Drive Simulation Board User s Guide 102 Connector Assignment and Display Elements ETAS...
Страница 110: ...ES5340 2 Electric Drive Simulation Board User s Guide 110 Order Information and Scope of Delivery ETAS...
Страница 116: ...ES5340 2 Electric Drive Simulation Board User s Guide 116 ETAS Contact Addresses ETAS...
Страница 118: ...ES5340 2 Electric Drive Simulation Board User s Guide 118 Figures ETAS...