ETAS
Technical Data
ES441.1 - User Guide
94
8.1.3
Environmental Conditions
8.1.4
Maintenance the Product
Do not open or change the module! Works on the module housing may be exe
-
cuted only by qualified technical personnel. Send defect modules to ETAS.
ISO 16750-4, Sec. 5.4.2
Splash water
Air temperature: To +120 °C,
Cycle duration: 30 min,
Splash length: 3 s,
Splash quantity: ca. 3 l,
Splash water temperatur:
+2 °C ± 2 °C,
Medium: water, put in 3% Arizona dust
fine,
Number of cycles: 100,
Unit under test: active
ISO 16750-4, Sec. 5.5.1.;
DIN EN 60068-2-52
Salt fog:
Severity level: 5,
Test duration: 16 d,
Units under test: passive
ISO 16750-5
Chemical resistance:
Identification A-W,
Prüflinge passiv
DIN 5596-1
Stone impact
IPX7
Protection class test:
Protection class IP67 (with cables
connected)
EN61000-4-2
Immunity ESD
EN61000-4-3
Immunity radiated RF
EN61000-4-4
Immunity EFT/B
EN61000-4-5
Immunity surge
EN61000-4-6
Immunity conducted RF
DIN EN 55022
Emission radiation/ radio interference
voltage
Operating temperature range
-40 °C to +120 °C
-40 °F to +248 °F
Storage temperature range
(module without packaging)
-40 °C to +125 °C
-40 °F to +257 °F
Altitude
max. 5000 m / 16,400 ft
Protection class
IP67
CAUTION
Loss of Features as defined by IP67!
Do not open or change the module!
Works on the module may be executed only by qualified technical personnel.
Norm
Test