Installation
Dismantling the boiler (if required)
43
Remove the boiler's covers
Remove the left cover from the boiler.
Fig. 9-12: Cover
Remove the rear cover from the boiler.
Fig. 9-13: Cover
Removing the screen for the ETAtouch control
system
Disconnect the data cable for the screen from the
circuit board [GM-C] at terminal [S510]. Unthread the
network cable from the cable ducts. The cables can
stay connected to the screen.
Fig. 9-14: Disconnecting the cables
Loosen the screws on the screen bracket and store
them in a safe location along with the cables.
Fig. 9-15: Remove the screen