Buffer storage tank
Connection between multiple buffer storage tanks
31
With stratified charging module and fresh water
module
1
Fresh water module flow
2
Temperature sensor [Sensor 1 (upper)]
3
Boiler, heating circuits, oil/gas boiler flow
4
Solar flow, top
5
Temperature sensor [Sensor 2]
6
Oil/gas boiler return
7
Temperature sensor [Sensor 3]
8
Solar flow, lower
9
Boiler, high-temperature circuit return
10 Temperature sensor [Sensor 4]
11 Fresh water module return, solar
12 Low-temperature circuits return
8.3
Connection between multiple
buffer storage tanks
Parallel connection
When there are several buffers, parallel connection
(top with top and bottom with bottom) is usually the
better solution. With a parallel connection, the entire
buffer volume is available to installed heat exchangers
such as solar heat exchangers or internal water heat
exchangers and suspended hot water tanks.
If two buffer storage tanks of different dimensions are
connected in parallel, then the flow must be connected
to the higher buffer or the lower buffer must be raised
so that the upper connection can be horizontal.
1
Flow
2
Solar heating system flow
3
Return
4
Solar heating system return
5
Return
Содержание PelletsCompact PC33
Страница 1: ...2020 07 21 EN 0000000171 V 025 2707 93113 005 PelletsCompact 33 50 kW Installation...
Страница 33: ...Buffer storage tank Connection between multiple buffer storage tanks 33...
Страница 51: ...Installation Network connection 51...
Страница 55: ...Electrical connections Overview of circuit boards 55...
Страница 74: ...www eta co at...
Страница 75: ......
Страница 76: ...www eta co at www eta co at downloads DOWNLOAD...