![eta Hack 200 kW Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/eta/hack-200-kw/hack-200-kw_service-manual_2430170027.webp)
Cleaning and maintenance
Maintenance (expert)
27
2.6.4
Check air valve
Remove the cover on the front
Remove the screws for securing the cover. Push the
cover on the front up slightly, detach and remove it.
Fig. 2-55: Cover
Check air valve
Manually operate both air valve actuators and check
their movement.
Fig. 2-56: Air valve actuators
For manual operation, push the release button (red
button) and manually turn the actuator through 90°
with the set screw.
Fig. 2-57: Manual operation of actuator
If there is resistance in the movement of the air
valves, lubricate only with dry lubricant (e.g.
PTFE spray).
Содержание Hack 200 kW