Cleaning and maintenance
Regular maintenance
11
Open the fasteners on the lids and empty the ash bins.
Fig. 2-3: Check ash
If there are large pieces of slag in the ash, the
combustion chamber and the tilting grate must be
checked and the de-ashing interval reduced, if
necessary.
Inspect the seal in the ash bin lids to ensure it is in
good order, and replace if necessary.
Fig. 2-4: Seal
Inspect the ash bin seals on the boiler to ensure they
are in good order, replace them if necessary.
Fig. 2-5: Seal
Attach the ash bins to the boiler
Reattach the cover to the ash bins and secure with the
fasteners. Then re-open the covers in the lids.
Fig. 2-6: Covers
Push the ash bins over the connections on the boiler
and attach to the boiler with the lever.
Fig. 2-7: Attach the ash bins to the boiler with the lever