ETAtouch controller
Up to software version X.35.X
33
10.1.1.3
Operation
Setting charging times and temperatures of the
fresh water module
With the [Stand-by times] timer, you can set different
time windows and hot water temperatures for the fresh
water module for each day of the week.
Within these time windows, the upper part of the
accumulator tank is maintained at no less than
the set hot water temperature.
Outside the set time windows, the hot water is
maintained at the lowest set temperature of the 3 time
windows, provided that the accumulator tank is suffi-
ciently hot.
To set the charging times and temperatures, tap the
overview
screen
on
the
[Stand-by
times]
timer. A screen
opens.
Fig. 10-1: Overview of hot water charging times
Set the hot water temperature as low as possible
to prevent limescale build-up.
You can find further details about setting the time
window in chapter
Setting circulation times for the circulation pump
With the [Circulation times] timer, you can set 3
different time windows for the circulation times of the
circulation pump for each day of the week.
To set the circulation times, tap the [Circulation times]
timer in the
overview screen. A screen opens.
Fig. 10-2: Overview of circulation times
Set the circulation times to be as short as
possible to ensure good buffer stratification and
prevent limescale build-up.
You can find further details about setting the time
window in chapter
.