Installation
Installing the pellet bin
45
Inspect the stoker seal to ensure it is intact; replace it
if necessary.
Fig. 9-21: Seal
Place the pellet hopper over the stoker and lower
evenly with the aid of the levelling feet. Fasten the
pellet hopper to the stoker with nuts. Tighten the nuts
alternately and evenly.
Check the alignment of the pellet hopper and correct it
with the levelling feet, if necessary.
Fig. 9-22: Checking the alignment
Rotating the connections for pellet hoses
If required, the pellet hose connections can be rotated
by 90° or 180°. If this is necessary, carry out the
following steps.
1. Push up the rear cover and remove it.
Fig. 9-23: Cover
2. Dismantle the side panels.
Fig. 9-24: Side panels