Installation
Mount flue gas connection
41
The pellet module may not be lifted on the pellet
nozzles as they would be damaged in the
process.
Fig. 9-3: Do not lift on the pellet nozzles
An optional sound-insulation set is available
An optional sound-insulation set is available for
the boiler. If you use this, insert the sound-
insulation strips longitudinally under the boiler's base
frame and also under the stoker's levelling screws.
9.2
Mount flue gas connection
Mounting the flue gas connection
Remove the cover from the top of the boiler.
Fig. 9-4: Cover
Check the flue gas connection seal for damage. Attach
the flue gas connection to the boiler with the nuts.
Tighten the nuts alternately and evenly.
Fig. 9-5: Flue gas connection
Mount the flue gas temperature sensor and secure it
with the screw. Only hand-tighten the screws so as not
to damage the temperature sensor.
Fig. 9-6: Flue gas temperature sensor
Fig. 9-7: Screw