51
Displayed on screen.
Definition.
Solution.
Collision Timer
More than 4 collisions detected in a row, 10s timer prevents
subsequent triggers.
Remove physical obstruction.
Condominium Mode
Lock not allowed
Holiday lockout not allowed in Condominium mode.
Change BT mode to a mode that allows holiday lock-
out.
Crawl distance
= 0mm
Crawl distance is the distance the gate runs as slow speed at
either end, longer crawl improves safety.
Use longer crawl distances for heavier free moving
gates.
Enable beam
for auto-close
auto-close can not be used without beams.
This is for safety, an IEC requirement.
Encoder error
There was an error detecting the motor encoder.
Ensure control card and ring magnet are securely
fastened.
Erase address
Comms Error
No data seen on RF.
If persistent, bring control card in for repair.
Erase ALL
Comms Error
An error occurred when trying to communicate to the receiver
module.
If persistent, bring control card in for repair.
ERROR: BAT
voltage too high
BAT voltage high error. (when trying to run gate)
The BAT voltage is too high and may cause damage to
the motor drive circuitry.
ERROR: No high
current source
Only low current power supply available.
No PSU or battery attached. Check wiring.
ERROR: PSU
voltage too high
PSU voltage high error. (when trying to run gate)
The PSU voltage is too high and may cause damage to
the motor drive circuitry. Check 220Vac supply.
ERROR: RF comms
No data seen on RF.
If persistent, bring control card in for repair.
Factory Reset
A factory reset was performed.
Reconfigure control card programming and setup.
Find Limit
The gate is searching for the limit.
Allow gate to continue all the way closed.
Finding closed
limit
Gate is running slowly to the closed limit.
Allow gate to continue all the way closed.
Flash mem error
Reprogram board
Flash memory corrupt, reprogram the board.
Bring control card in for repair.
Gate re-profile
required
The gate run-time setup needs to be re-done.
This is required when changing parameters that affect
how the gate runs and hence the overload sensing.
Holiday Locked
Holiday Lockout enabled.
Deactivate as per page 43.
IEC Mode Error
No Beams
IEC mode has been enabled but there is an error.
Beams have been removed after enabling IEC mode,
repair beam circuit.
Ill opcode Reset
Processor reset due to a software error.
If persistent, bring control card in for repair.
Learn Abort
Indicates that Learning gate length failed.
Restart runtime setup.
Learn Aborted
Runtime setup aborted for some reason.
Restart runtime setup.
Learn Error
Beam
Runtime setup failed because the beams were interrupted.
Restart runtime setup.
Learn Error
Button Exit
Runtime setup failed because exit button was pressed.
Restart runtime setup.
Learn Error
Gate Too Long
Runtime setup failed because gate length is >40m.
Reduce gate opening distance before attempting
runtime setup again.
Learn Error
Gate Too Short
Runtime setup failed because gate length is <1m.
Increase gate opening distance before attempting
runtime setup again.
Learn Error
Limit Range
Runtime setup failed because the limit is out of range.
Limit moved or considerable rack jumping. Refasten
limit actuator.
Learn Error
Manual Released
Runtime setup failed because manual release lever was
actuated.
Re-engage manual override or repair manual override
monitoring circuit.
Learn Remote
Err: Time-out
No ET Blue or ET BluMix remote detected within 2s.
Check that you are using a matching frequency ET
Blue or ET BLU MIX transmitter that is functional.
Learn Remote
Err:Decode error
Invalid remote detected.
You can only use ET Blue or ET BLU MIX transmitters.
Learn Remote
Err:RSSI TimeOut
No remote detected within 2s.
Check that you are using a matching frequency ET
Blue or ET BLU MIX transmitter that is functional.
Limit faulty
The limit sensor is faulty.
Shown when no limit is found within the expected
limit window.
Limit Range
Err
Closed limit not detected within an acceptable range.
Limit moved or considerable rack jumping. Refasten
limit actuator.
Manual Released
Manual release lever activated.
Re-engage manual override or repair manual override
monitoring circuit.