background image

32

User manual reference - Page 

Safety infra-red beams function.

All modes except P.I.R.A.C.

Basic operating 

features

If the safety beam input has been switched on, the control card will constantly monitor to ensure a set of safety beams is installed.

NB!

 If the BT input mode has been set to either simple auto-close or condominium mode, the safety beam input is forced on.

If the loop detector input is activated, the safety beam input is forced on for that transaction only.

Below is an example of how the gates will behave whenever the safety beam input is activated.

Action

Response

Momentary BT trigger.

Gate begins 

opening.

No buzzer tones.

Safety beam input 

triggered while gate is 

opening.

Gate continues 

opening

No buzzer tones.

At full open position.

Safety beam input still 

triggered.

Gate stops and 

waits for next 

trigger to close.

No buzzer tones.

Momentary BT trigger.

Trigger is 

ignored and 

gate remains 

open.

No buzzer tones.

Safety beam input 

cleared.

Gate remains 

in the full open 

position until 

the next trigger 

to close.

No buzzer tone.

Momentary BT trigger.

Gate begins 

closing.

No buzzer tone.

Safety beam input while 

the gate is closing.

Gate stops and 

reverses open.

No buzzer tone.

At the full open 

position.

Gate stops and 

waits for next 

trigger to close.

No buzzer tone.

Momentary BT trigger.

Gate begins 

closing.

No buzzer tone.

User manual reference - 

Page 7 

Safety infra-red beams function.

All modes except P.I.R.A.C.

Basic operating 

features

If the safety beam input has been switched on, the control card will constantly monitor to ensure a set of safety beams is installed.

NB!

 If the BT input mode has been set to either simple auto-close or condominium mode, the safety beam input is forced on.

If the loop detector input is activated, the safety beam input is forced on for that transaction only.

Below is an example of how the gates will behave whenever the safety beam input is activated.

Action

Response

Momentary BT trigger.

Gate begins 

opening.

No buzzer tones.

Safety beam input 

triggered while gate is 

opening.

Gate continues 

opening

No buzzer tones.

At full open position.

Safety beam input still 

triggered.

Gate stops and 

waits for next 

trigger to close.

No buzzer tones.

Momentary BT trigger.

Trigger is 

ignored and 

gate remains 

open.

No buzzer tones.

Safety beam input 

cleared.

Gate remains 

in the full open 

position until 

the next trigger 

to close.

No buzzer tone.

Momentary BT trigger.

Gate begins 

closing.

No buzzer tone.

Safety beam input while 

the gate is closing.

Gate stops and 

reverses open.

No buzzer tone.

At the full open 

position.

Gate stops and 

waits for next 

trigger to close.

No buzzer tone.

Momentary BT trigger.

Gate begins 

closing.

No buzzer tone.

Gate closed.

Содержание DRIVE 1000

Страница 1: ...ET DRIVE1000 INSTALLER 2016 001 003 Installer Instructions High Traffic 1000kg Slide Gate Operator www et co za...

Страница 2: ...e Page 22 Receiver programming and setup Page 29 Advance programming options and their definitions Operating mode definitions and examples Page 31 Collision sensing and safety overload routines Page 3...

Страница 3: ...ns of mechanical ends of travel stoppers 5 Ensure all fixed mounting points such as the wall above the door in a garage door system or the posts in a swing gate system are sound and strong enough to a...

Страница 4: ...d in at a battery merchant for safe disposal Before removing the battery from the system the household mains must be disconnected In the case of the motor unit being removed and scrapped the battery m...

Страница 5: ...put 3 Plug in terminal connectors 12 Manual override access hatch 4 ACDC power pack 13 Manual override access hatch lock 5 Battery 14 Electric motor 6 Levelling and height adjusting bolts 15 Electric...

Страница 6: ...ad in nylon be used The guidance system should be installed at the top edge of the gate whenever possible In cases where this is not possible the guidance system should never be below the halfway poin...

Страница 7: ...Rolling Resistance Max Duty Cycle Drive 1000 ACDC option 1000 kg 40 kgf 30 kgf 98 Drive 1000 Battery dependent option 1000 kg 40 kgf 30 kgf 25 Where to position the gate motor Liquid ingress The ET D...

Страница 8: ...there 1 29V 3 Alarm panel 2 11 4 10 8 9 1 6 5 7 1 Courtesy lights twin earth 1 0mm back to motor housing and isolator switch 7 Free exit loop 1 5mm silicone insulated single core flexible stranded ca...

Страница 9: ...he concrete must cure properly before continuing with the installation Whichever mounting method you opt for the position of the base plate will always remain the same Here are the dimensions to use w...

Страница 10: ...2 Unlock and open the manual override hatch 3 Lift the main cover to remove it Mounting the gearbox You will need a 13mm socket or spanner and a 5mm Allen hex key The gearbox is fastened onto the base...

Страница 11: ...the manual override hatch closed and locked up To disengage the gearbox Manual mode 1 Raise lock cover 2 Insert the key 3 Turn the key clockwise 4 Open the manual override hatch 5 Swing manual overrid...

Страница 12: ...he wheel shrinkage will cause the gate to sit heavier on the pinion or when the rack is no longer square to the pinion due to gate flex False safety sensing activation The following shows a simple met...

Страница 13: ...closed until the next length of rack meets the first length and the opposite end once again rests on the pinion To ensure the 2 lengths of rack marry correctly use an off cut of rack clamped upside do...

Страница 14: ...C O C certificate of compliance by a registered electrician In the case of the plug in transformer being used where the low voltage 29Vac is run to the gate there is no need for the all pole isolator...

Страница 15: ...0 Safety beam RX Com N C N O N O N O Loop detector Non polarity sensitive termination for 2 wire Bluebus devices For example safety beams 24V 5Ah Battery Standard in kit Optional 24V 3 5Ah Battery 24V...

Страница 16: ...0 machine bolt upside down on top of the spine of the rack in line with the limit switch 3 Fasten the actuator down onto the rack using either the M4 x 20mm self tapping screw supplied with the kit or...

Страница 17: ...t all the way back to standby without saving when in programming Enter programming advance to next level of option on display save value on display Control card programming and setup 1 Runtime setup P...

Страница 18: ...s reached and the closed limit is triggered LED on Gate stops and starts opening Display prompts you to stop the gate in the open position Learning length Press at open Press and release the button to...

Страница 19: ...to programming menu options list Overload Setting change x2 x1 x1 Scroll left or right to next program option OR Selected mode Standby EXIT back to standby status x2 Safety infra red beams setup Beam...

Страница 20: ...Setting on the display press and release Display shows current option status BT Mode Setting Standard Scroll or to the required BT mode option Display changes respectively BT Mode Setting Standard BT...

Страница 21: ...ions Scroll or to select the pedestrian setting option Display scrolls through options Ped Mode Setting change With Ped Setting on the display press and release Display shows current pedestrian openin...

Страница 22: ...ceiver Setup Quick learn With Quick learn on the display press and release Display prompts you to select a function Select function BT Full opening Scroll or to the required receiver function channel...

Страница 23: ...and hold any button on the remote transmitter All four buttons must be set to the same format for this to work in the same way as this example While still transmitting with the remote button press an...

Страница 24: ...splay press and release Display prompts you to select an available user address Select address 1 used Scroll or to select an available user address Display changes respectively Select address 2 With a...

Страница 25: ...display press and release Display shows first erase option Erase Remotes Select Address With Select Address on the display press and release Processor scans the memory and then displays the first avai...

Страница 26: ...Scroll or to select the Erase ALL memory option Display scrolls through options Erase Remotes Erase ALL memory With Erase ALL memory on the display press and release Display then prompts you to press...

Страница 27: ...release Display prompts you to press and release a remote button Diagnose Remotes Press Remote After prompt Display shows a signal strength graph and waits for a remote transmission Signal Not recogni...

Страница 28: ...splay press and release Display shows receiver setup options Receiver Setup Quick learn Scroll or to select the Receiver info option Display changes respectively Receiver Setup Receiver info With Rece...

Страница 29: ...timising the external battery and charger s performance AC monitoring This option allows you to disable the Vac mains failure monitoring on sites where a solar panel system has been installed to maint...

Страница 30: ...troller settings to the last saved restore point Clear logs Use this feature to clear the event fault and trigger logs NB this does not clear the cycle counter Factory reset Use this feature to defaul...

Страница 31: ...es with a pedestrian for example Gate stops opening Once gate has stopped Gate reverses momentarily to release pressure No buzzer tones After reversing momentarily Gate stops and waits for next trigge...

Страница 32: ...r next trigger to close No buzzer tone Momentary BT trigger Gate begins closing No buzzer tone User manual reference Page 7 Safety infra red beams function All modes except P I R A C Basic operating f...

Страница 33: ...to each BT trigger In Standard mode you have access to the following advanced features Holiday lock out and Party mode Action Response Momentary BT trigger Gate begins opening No buzzer tones At full...

Страница 34: ...rty mode NB For any auto close feature to work a pair of safety infra red beams must be installed and functioning correctly If no safety infra red beams are installed then the gates will open but not...

Страница 35: ...ng correctly If no safety infra red beams are installed then the gates will open but not close again Action Response Momentary BT trigger Gate begins opening No buzzer tones Momentary BT trigger while...

Страница 36: ...ty infra red beams must be installed and functioning correctly If no safety infra red beams are installed then the gates will open but not close again Action Response Momentary BT trigger Gate begins...

Страница 37: ...trian transaction is cancelled The system then reverts to either the Loop or BT trigger mode depending on which was triggered There are two ways of activating the PED functions on this control card Ei...

Страница 38: ...he Loop or BT trigger mode depending on which was triggered There are two ways of activating the PED functions on this control card Either via the hardwired PED input or the PED receiver channel Actio...

Страница 39: ...not close again Action Response Loop trigger Gate begins opening No buzzer tones Momentary BT trigger or Loop trigger while gate is opening The trigger is ignored and the gate continues opening No bu...

Страница 40: ...d battery of the control unit Below is an example of strike lock mode when standard BT mode is active Action Response Momentary BT trigger Auxiliary relay activates No buzzer tone Half a second after...

Страница 41: ...an damage the charger and battery of the control unit Below is an example of magnetic lock mode when standard BT mode is active Action Response Momentary BT trigger Auxiliary relay activates No buzzer...

Страница 42: ...e Action Response Momentary BT trigger Auxiliary relay activates No buzzer tone Gate begins opening Gate reaches open position Gate stops No buzzer tone Momentary BT trigger Gate begins closing No buz...

Страница 43: ...y Relay receiver function is pressed and released Latch mode The transmitter must be released and pressed again to reactivate the relay each time Action Response Momentary relay trigger Auxiliary rela...

Страница 44: ...esponse Momentary BT trigger Gate begins opening No buzzer tones At full open position Gate stops No buzzer tones Momentary BT trigger Gate begins closing No buzzer tones Momentary BT trigger Gate sto...

Страница 45: ...Response Momentary trigger from any transmitter button programmed into holiday lock out function Buzzer begins toning and status LED comes on BT button while buzzer is sounding to confirm that you wa...

Страница 46: ...ction Buzzer begins toning and status LED comes on BT button while buzzer is sounding to confirm that you want to activate holiday lock out If no BT button is pressed during this 5 second window the a...

Страница 47: ...armed response standby point or to the nearest police station This way they can ask for an escort onto the property Safety beam alarm mode is available in all modes of operation so long as a set of sa...

Страница 48: ...abled On Off Status LED indications and buzzer guide Description Visual confirmation Buzzer Reason Static off None Gate fully closed Flashing slow 1 second on and 1 second off None Gate running normal...

Страница 49: ...ent charger stage Bat Curr limit Battery charger status Charger is in current limiting Battery is level is low or there is a battery wiring fault Bat Err FET shrt Battery charger status The charger FE...

Страница 50: ...ed as this is not monitored Not IEC compliant Beam Test Monitored LF N C Low frequency switched beam monitoring with Normally closed contacts wiring detected High safety option IEC compliant Beam Test...

Страница 51: ...d when changing parameters that affect how the gate runs and hence the overload sensing Holiday Locked Holiday Lockout enabled Deactivate as per page 43 IEC Mode Error No Beams IEC mode has been enabl...

Страница 52: ...pen on a pedestrian trigger Page 21 Power error braking Device is about to shut down due to low power motor is slowing down Low AC PSU and Bat voltages Power error resetting Device is about to shut do...

Страница 53: ...zed non manufacturer modifications to the product or components thereof 2 Any modification to the installation methods described in the installation instructions 3 Any application or use of the produc...

Отзывы: