Auxiliary relay modes.
Strike lock mode.
Basic operating
features
With Strike lock mode selected, the auxiliary relay will pulse for the preprogrammed on time, half a second before the gate opens.
Whenever a lock is installed with the system, a separate battery backed up power supply matching the lock load must be installed. Failure to do this
can damage the charger and battery of the control unit.
Below is an example of strike lock mode when standard BT mode is active.
Action
Response
Momentary BT trigger.
Auxiliary relay
activates.
No buzzer tone.
Half a second after
the auxiliary relay has
activated.
Gate begins
opening.
No buzzer tone.
After the
preprogrammed relay
on time.
Auxiliary relay
deactivates and
gate continues
opening.
No buzzer tone.
Gate reaches open
position.
Gate stops.
No buzzer tone.
Momentary BT trigger.
Gate begins
closing.
No buzzer tone.
At full closed position.
Gate stops.
No buzzer tone.
ON
Com
N/O
N/C
OFF
Com
N/O
N/C
0
0.5 sec.
0
1 sec.
Gate closed.