2 7
user manual LokSound / LokSoundXL V3, 1st edition, 07/2004
List of all supported CVs
19 Consist address
Additional address for consist
0-127
0
value 0 or 128 means: consist address deactivated
1-127 consist address, normal direction
129-255 consist address, reverse direction
29 Configuration register The most complex CV within the DCC standards.
4
This register contains important information,
which is only relevant in DCC mode.
Bit function
value
0 Reverse direction of travel
(forward becomes reverse)
normal direction
0
reversed direction
1
1 speed steps (only for DCC mode)
14 speed steps
0
28 or 128 speed steps
2
2 analogue operation
analogue operation off
0
analogue operation on
4
4 selection of speed curve
speed curve through CV 2,5, 6
0
speed curve through CV 67 – 96
16
5 selection of engine address (only for DCC operation)
short addresses (CV 1) in DCC mode
0
long addresses (CV 17 + 18) in DCC mode
32
49 Extended configuration Activate support for brake sections
19
or switch off Back EMF control
Bit description
value
0 load control off
0
load control activated
1
1 DC motor PWM frequency
15 kHz pulse frequency
0
30 kHz pulse frequency
2
2 Märklin® delta mode
Delta mode off
0
Delta mode on
4
3 Märklin® second address
second address off
0
second address on
8
4 Automatic speed step detection
DCC speed step detection off
0
DCC speed step detection on
16
5 LGB function button mode
LGB mode off
0
LGB mode on
32
6 Zimo manual function
Zimo manual function off
0
Zimo manual function on
64
CV name
description
range
default