990ELX-I02-220319
Calibrating the induction unit
Before using your induction hob, you must ‘calibrate’ the sensitivity
of the controls. It is crucial that this is done correctly, to ensure that
the induction hob operates appropriately.
To calibrate the controls on your induction unit please follow the
below steps:
1.
Ensure that the power to your ESSE 990 ELX is switched
off at the wall.
2.
Turn the power to your ESSE 990 ELX on at the wall.
a.
The induction hob will run through a start-up
routine for a few seconds, during which time all
the numerical LEDs will show ‘8’.
b.
When the start-up routine is complete, a single
LED above the ‘lock button’ on the control panel
will be lit up.
3.
Firmly press the ‘lock button’ for 2 seconds, until the LED
goes out.
Your ESSE 990 ELX induction hob controls are now successfully
calibrated
You must recalibrate the induction hob controls every
time power is lost. I.E. when your ESSE 990 ELX is
switched off at the mains, or there is a power cut.