OMNI-Test Laboratories, Inc.
Q
sd
– Average gas flow rate in dilution tunnel, dscf/hr
ASTM E2515 equation (3)
Where:
3600
=
Conversion from seconds to hours (ASTM method uses 60 to convert in minutes)
B
ws
=
Water vapor in gas stream, proportion by volume; assume 2%
A
=
Cross sectional area of dilution tunnel, ft
2
T
std
=
Standard absolute temperature, 528
°
R
P
s
=
Absolute average gas static pressure in dilution tunnel, = P
bar
+ P
g
, in Hg
T
s(avg)
=
Absolute average gas temperature in the dilution tunnel,
°
R; (
°
R =
°
F + 460)
P
std
=
Standard absolute pressure, 29.92 in Hg
Sample calculation:
-0.24
13.6
76.8 + 460
Q
sd
=
13535.7
dscf/hr
29.92
20.17 x 0.196
x
528
x
29.5 +
Q
sd
= 3600 x (1 - 0.02) x
std
s
avg
s
std
s
ws
sd
P
P
T
T
A
v
B
Q
)
(
)
1
(
3600
Control No. P-SSAR-0003
Low Burn Run 2
104 of 161
Содержание BakeHeart
Страница 34: ...34 of 161...
Страница 35: ...35 of 161...
Страница 42: ...42 of 161...
Страница 43: ...43 of 161...
Страница 52: ...52 of 161...
Страница 53: ...53 of 161...
Страница 60: ...60 of 161...
Страница 61: ...61 of 161...
Страница 70: ...70 of 161...
Страница 71: ...71 of 161...
Страница 75: ...75 of 161...
Страница 76: ...76 of 161...
Страница 77: ...77 of 161...
Страница 78: ...78 of 161...
Страница 79: ...79 of 161...
Страница 80: ...80 of 161...
Страница 81: ...81 of 161...
Страница 82: ...82 of 161...
Страница 83: ...83 of 161...
Страница 85: ...85 of 161...
Страница 86: ...86 of 161...
Страница 87: ...87 of 161...
Страница 94: ...94 of 161...
Страница 96: ...96 of 161...
Страница 97: ...97 of 161...
Страница 113: ......
Страница 114: ...Bakeheart and Warmheart Wood Fired Cook Stove Owner s Manual OMNI Test Laboratories Inc 0224WS009S 0224WS009E...
Страница 159: ......