OMNI-Test Laboratories, Inc.
Manufacturer:
Model:
Run:
Category:
BR – Dry burn rate, kg/hr
V
s
– Average gas velocity in the dilution tunnel, ft/sec
Q
sd
– Average gas flow rate in dilution tunnel, dscf/hr
V
m(std)
– Volume of gas sampled, corrected to dry standard conditions, dscf
m
n
– Total particulate matter collected, mg
C
s
- Concentration of particulate matter in tunnel gas, dry basis, corrected to standard conditions, g/dscf
E
T
– Total particulate emissions, g
PR - Proportional rate variation
PM
R
– Particulate emissions for test run, g/hr
PM
F
– Particulate emission factor for test run, g/dry kg of fuel burned
Equations and Sample Calculations – ASTM E3053 & E2515
ESSE
WarmHeart
2
Low
are provided for each equation. The raw data and printout results from a sample run are also provided for
Equations used to calculate the parameters listed below are described in this appendix. Sample calculations
comparison to the sample calculations.
Control No. P-SSAR-0003
Low Burn Run 2
101 of 161
Содержание BakeHeart
Страница 34: ...34 of 161...
Страница 35: ...35 of 161...
Страница 42: ...42 of 161...
Страница 43: ...43 of 161...
Страница 52: ...52 of 161...
Страница 53: ...53 of 161...
Страница 60: ...60 of 161...
Страница 61: ...61 of 161...
Страница 70: ...70 of 161...
Страница 71: ...71 of 161...
Страница 75: ...75 of 161...
Страница 76: ...76 of 161...
Страница 77: ...77 of 161...
Страница 78: ...78 of 161...
Страница 79: ...79 of 161...
Страница 80: ...80 of 161...
Страница 81: ...81 of 161...
Страница 82: ...82 of 161...
Страница 83: ...83 of 161...
Страница 85: ...85 of 161...
Страница 86: ...86 of 161...
Страница 87: ...87 of 161...
Страница 94: ...94 of 161...
Страница 96: ...96 of 161...
Страница 97: ...97 of 161...
Страница 113: ......
Страница 114: ...Bakeheart and Warmheart Wood Fired Cook Stove Owner s Manual OMNI Test Laboratories Inc 0224WS009S 0224WS009E...
Страница 159: ......