SERVICE
52
S13 Wiring Diagram
Страница 1: ...INSTALLATION SERVICE INSTRUCTIONS KS1150 Peninsula 400 Gas Fireplace 630458_1 KS1150 Peninsula 400 Install Manual...
Страница 2: ...ct Installation must be carried out by a registered installer who on completion of the installation must issue a AUS Certificate of Compliance NZ Certificates that comply with the latest legislation i...
Страница 3: ...Middle 1 25mm Burner Aeration LH RH Closed Collars Middle Closed Collar LH RH 2 x 6mm Middle Spacer no restriction LH RH 2 x 6mm Middle Spacer no restriction Pilot injector 42 27 27 Appliance Dimensio...
Страница 4: ...ternal Vertical Powerflue UVP 15 C5 Installing the External Vertical Powerflue UVP 17 C6 Installing in Accordance with Relevant Codes 18 C7 Running the Flue 19 C8 Running the Powerflue Electrical Cabl...
Страница 5: ...liance 39 F9 Normal Operating Sounds and Smells 40 G Installation Checklist 41 S Service Manual 42 S1 Annual service procedure 42 S2 Error Codes 43 S3 Cleaning the Fuel bed and Glass 45 S4 Checking Op...
Страница 6: ...Radio Frequency RF remote that will normally be located in its wall mount cradle In addition to the RF remote the appliance has a single auxiliary On Off button on the unit When not in operation it i...
Страница 7: ...lue configuration Flue exhaust fan noise Exhaust cowl access for maintenance Gas pipe layout Gas isolation valve pressure test point position Electrical isolation switch Home automation network connec...
Страница 8: ...s B6 Television Mantel Clearances Television The diagram shown right shows the recommended minimum clearances for the location of any electrical equipment such as Plasma TV LCD TV or home theatre abov...
Страница 9: ...horizontal power flue enclosure kit The horizontal offset of the terminal can be any amount up to the total flue length listed below Please consult with Escea s technical staff if your intended flue c...
Страница 10: ...Escea universal vertical power flue enclosure kit 0 4m Min 4m Max Overall flue length Liner UVP Unit 4m MAX 1 2m Co axial Flue 4m MAX Vertical PowerFlue Cowl Duravent External MAX m Co axial Flue 4m...
Страница 11: ...YPRO FLUE SEE POLYPRO FLUE INSTALLATION INSTRUCTIONS AVAILABLE ON WWW ESCEA COM OR SUPPLIED WITH THE FLUE FOR POLYPRO COMPONENT GUIDES THESE ARE AVAILABLE ON WWW ESCEA COM TITLED HORIZONTAL FLUE COMPO...
Страница 12: ...lete to prevent damage to the dwelling It must be installed by a suitably qualified person Fit the horizontal powerflue wall terminal into the hole and fix in place making sure the installation is sea...
Страница 13: ...A From the front of the terminal B By attaching the optional wall terminal installation brackets to the sides of the cavity and attaching the horizontal powerflue wall terminal to these from the fron...
Страница 14: ...wrap to opening seal air gap to opening terminal screw fixed to flange with flange fixed to studs at fixing brackets packer to lift terminal off sill sill cover to cladding to comply with relevant bui...
Страница 15: ...ng powered flue termination rules Mount the fan mount bracket 1 to the roof framing and strapping using timber ensuring that the flue is rigid and vertical Ensure that the mounting timber does not obs...
Страница 16: ...e access must be provided Ensure installation complies with relevant building codes and regulations To appliance Typical Installation UVP Cowl Decktite or similar flashing 1 2m F F Liner Hose band cla...
Страница 17: ...d length ENSURE the 25mm restriction plate is installed on the inlet The cowl surround should be fixed in place as shown Mount the UVP kit to the top of a chimney flashing plate or penetrate the roof...
Страница 18: ...Horizontally from any building structure or obstruction 500mm H From any other flue terminal or combustion air intake 300mm J Horizontally from any moving window door non mechanical air inlet or any o...
Страница 19: ...uminium flue to allow it to protrude through the wall ceiling roof flue liner to enable it to be connected to the powerflue terminal The flue should be expanded at each end in order for the flue to be...
Страница 20: ...t is not draped over or in contact with the outer shell of the appliance or the flues The cable must be kept clear from any other possible heat sources sharp edges or moisture Fix it appropriately and...
Страница 21: ...ly to the appliance after it has been fully installed This appliance must not be located immediately below a socket outlet This appliance will draw a maximum of 2 Amps from a 230 240V supply No additi...
Страница 22: ...S1150 Peninsula 400 Gas Consumption 33MJ hr D4 Gas Pipe Position The gas connection is inside the appliance and is male BSP on the lower right of the appliance as shown below Access is through the sil...
Страница 23: ...s will also allow for easier servicing in the future END OF SECTION D By the end of this section you should have An unlined cavity with 230 240V AC supply where the appliance can be plugged into an el...
Страница 24: ...curely fastened at the base E3 Removing and Replacing the Glass Remove the glass by unscrewing the four 1 4 turn fasteners located at the top of the glass shown in the diagram below and remove the bra...
Страница 25: ...is not required then skip to the next section Your gas fire has been supplied with the necessary parts for gas conversion Follow the steps on the following pages to change from NG to ULPG Propane or v...
Страница 26: ...ate of manufacture are still visible Write your name company if appropriate and date of conversion on the new label with permanent marker Step 6 Replace the hatch removed in step 1 Take care not to ov...
Страница 27: ...fter the purge it will attempt ignition It may take a few attempts to light the first time due to air in the gas line You may wish to purge the gas line at the valve by bleeding the first test point T...
Страница 28: ...pressure post regulator Turn the fire on high and adjust the operating pressure at the regulator shaded grey in the diagram below Once the operating pressure post regulator is set check the operating...
Страница 29: ...sure measured at point A or D The large digits will blink rapidly after the setting is made until the verification is received from the fire Note The numbers displayed on the remote should only be use...
Страница 30: ...emote Control on page 45 of the service manual covers the steps necessary to pair a new remote Note Ensure the appliance has cooled down before using the manual on off button to avoid coming into cont...
Страница 31: ...as shown in section D2 Network Cable on page 21 Home Automation Operation Relay closed The fireplace will start in a medium setting until the remote control talks to the fireplace and picks up the ON...
Страница 32: ...can take up to 4 minutes While the relay is open the fireplace will be in standby mode and available for manual operation by the user END OF SECTION E By the end of this section you should have The ap...
Страница 33: ...log fuel bed you must have the correct retainers present before assembling the fuel bed The correct retainers are supplied with the fuel bed packaging First remove the infill by following section E4...
Страница 34: ...evenly after the logs have been located correctly excess flakes should NOT be added if one even layer has been achieved The flakes must not cover the pilot or pilot guard Note Improper positioning of...
Страница 35: ...e been located correctly excess flakes should NOT be added if one even layer has been achieved The flakes must not cover the pilot or pilot guard Note Improper positioning of any fuelbed media may cre...
Страница 36: ...A C D E F G SERVICE 36 Woodland Log Setup KS1150 Peninsula 400 Step 1 Step 2 Step 3 F5 Flame Picture An abnormal flame pattern will look long and stringy it may cause soot to build up inside the fireb...
Страница 37: ...rd that lines the outside of the opening can be normal plaster board and does not need to be non combustible The plasterboard is to protrude beyond framework as shown in the following diagram Note The...
Страница 38: ...a tidy manner for a nice Gib finish we recommend Gib Rondo stopping bead Note a 20mm or less wall lining must be used when installing a KS1150 Peninsula 400 fireplace A 10mm wall lining is recommended...
Страница 39: ...ce and within a few seconds the appliance will begin its startup sequence NOTE The appliance begins its startup with a 15 second pre start purge where the combustion fan runs on its own to clear the f...
Страница 40: ...e fire is switched off after being run for a while there may be popping and fluttering noises as the residual gas in the burners burns away These are normal and are no cause for concern Unit Body Fire...
Страница 41: ...rflue wall terminal leading back to the appliance and similar for vertical powerflue terminals The electrical cable from the powerflue terminal attached correctly and run back to the appliance cavity...
Страница 42: ...nd ensure correct gaps between electrode and pilot hood Remove burners and blow compressed air through the burner ports Remove jets and clean injector hole with solvent Vacuum any dust from the cavity...
Страница 43: ...e This error has a permanent lock out and will require the unit to be reset after the initial error turning the power to the fire off at the wall then on again after a few seconds Flame Failure or Pow...
Страница 44: ...d to be replaced Remote Cannot communicate with fire The remote cannot communicate with the fire Check if the fire is turned off at the wall i e a loss of power to the fire or the remote is outside of...
Страница 45: ...with only the time showing on the display press the MINUS PLUS and FAN BOOST buttons simultaneously as shown right until the characters 03 light up on the display Release the buttons The remote will...
Страница 46: ...the wireless remote under the batteries The second is on the data sticker on the chassis under the electronics tray S8 Removing or Cleaning Fan As part of regular service procedure it is recommended t...
Страница 47: ...hose and power cables S10 Pressure Switch Removal 1 Follow the steps in section E3 Removing and Replacing the Glass on page 24 on both the front and back of the appliance to remove the glass Follow t...
Страница 48: ...de glass retainer shown shaded below Loosen the 3 screws in the two bottom brackets circled below left Carefully remove the glass panel from the firebox by tilting the top out first 2 Remove the 10 sc...
Страница 49: ...m below The black tube should be connected between the grey side of the pressure switch and the low pressure port The translucent tube should be connected between the black side of the pressure switch...
Страница 50: ...off by disconnecting the power to the appliance inside If the appliance has been running allow the powerflue to cool before attempting to service it Servicing a Horizontal Powerflue Undo the screws o...
Страница 51: ...sal Vertical Powerflue If the UVP is internally installed remove the unit and replace the complete fan unit If the UVP is externally installed the cowl fan unit shown right is to be completly replaced...
Страница 52: ...B A C D E F G SERVICE 52 S13 Wiring Diagram...