B
A
C
D
E
F
G
SER
VICE
45
S3 Cleaning the Fuel bed and Glass
ALWAYS USE GLOVES WHEN HANDLING THE GLASS.
This is a service procedure that will need to be carried out whenever soot builds up on fuelbeds and/or
inside of glass.
If soot build up becomes excessive or regular then one of the following actions may be required:
•
Reset gas pressure, pressure may be too high;
•
Reposition fuelbed, check with specific fuelbed instructions for details;
•
Clear any blockage from primary aeration port of burner;
•
Check flue tube is not damaged or disconnected.
•
Check exhaust fan is operating and cowl is not blocked in any way.
S4 Checking Operating Pressure
See section E7 “Checking the Gas Operating Pressure” on page 27 of this manual.
S5 Replacing a Remote Control
If the wireless control becomes lost or damaged, a new one can be ordered from any Escea retail agent.
When you have the new remote, the following procedure needs to be followed to “teach” the remote
to only communicate with that fire.
1. Ensure the fire and remote are set to ‘OFF’ (only the time is displayed on the remote).
2. While the remote is in its ‘OFF’ mode with only the time showing
on the display, press the MINUS, PLUS, and FAN BOOST buttons
simultaneously (as shown right) until the characters “03” light up on the
display. Release the buttons. The remote will count down and display “GO”.
The screen will then display all characters and should be reading “00”. This
will put the remote into test mode.
Note: if the digits start counting then the
remote is already paired.
3. Press and hold the MINUS button until the two large temperature digits
reading “00” start to flash slowly. Release the MINUS button. The remote
control is now ready to be linked to the fire.
4. Press and hold the auxiliary on/off button on the fireplace for a minimum of ten seconds or until the
two large temperature digits start counting upwards from 00 to 99 repeatedly.
Note: Pressing the red auxiliary button on/off button will start the fire. Once the remote control is counting
the fire can be turned off by pressing the red auxiliary button again.
5. Press the large power button in the middle of the remote control to exit the test mode and return
to normal operation. The remote should only be displaying the time. Check the fire will start using the
remote control by pressing the large power button. Turn it off again using the remote control.
6. The fire is now linked to the remote control.
Содержание KS1150 Peninsula 400