background image

3

WARNING:

 T

hese Safety Precautions are for

your protection. They summarize precaution-
ary information from the references listed in
Additional Safety Information section. Before

performing any installation or operating procedures, be
sure to read and follow the safety precautions listed below
as well as all other manuals, material safety data sheets,
labels, etc. Failure to observe Safety Precautions can result
in injury or death.

PROTECT YOURSELF AND OTHERS

 --

Some welding, cutting, and gouging
processes are noisy and require ear
protection. The arc, like the sun, emits
ultraviolet (UV) and other radiation and

can injure skin and eyes.  Hot metal can cause burns.
Training in the proper use of the processes and equip-
ment is essential to prevent accidents. Therefore:

1. Always wear safety glasses with side shields in any work

area, even if welding helmets, face shields, and goggles
are also required.

2. Use a face shield fitted with the correct filter and cover

plates to protect your eyes, face, neck, and ears from
sparks and rays of the arc when operating or observing
operations. Warn bystanders not to watch the arc and
not to expose themselves to the rays of the electric-arc
or hot metal.

3. Wear flameproof gauntlet type gloves, heavy long-sleeve

shirt, cuffless trousers, high-topped shoes, and a weld-
ing helmet or cap for hair protection, to protect against
arc rays and hot sparks or hot metal. A flameproof apron
may also be desirable as protection against radiated
heat and sparks.

4. Hot sparks or metal can lodge in rolled up sleeves,

trouser cuffs, or pockets. Sleeves and collars should be
kept buttoned, and open pockets eliminated from the
front of clothing

5. Protect other personnel from arc rays and hot sparks

with a suitable non-flammable partition or curtains.

6. Use goggles over safety glasses when chipping slag or

grinding. Chipped slag may be hot and can fly far.
Bystanders should also wear goggles over safety glasses.

FIRES AND EXPLOSIONS -- Heat from
flames and arcs  can start fires. Hot slag
or sparks can also cause fires and ex-
plosions. Therefore:

1. Remove all combustible materials well away from the

work area or cover the materials with a protective non-
flammable covering. Combustible materials include wood,
cloth, sawdust, liquid and gas fuels, solvents, paints and
coatings, paper, etc.

2. Hot sparks or hot metal can fall through cracks or

crevices in floors or wall openings and cause a hidden
smoldering fire or fires on the floor below. Make certain
that such openings are protected from hot sparks and
metal.“

3. Do not weld, cut or perform other hot work until the

workpiece has been completely cleaned so that there
are no substances on the workpiece which might pro-
duce flammable or toxic vapors. Do not do hot work on
closed containers. They may explode.

4. Have fire extinguishing equipment handy for instant use,

such as a garden hose, water pail, sand bucket, or
portable fire extinguisher. Be sure you are trained in its
use.

SAFETY PRECAUTIONS

11/95

5. Do not use equipment beyond its ratings. For example,

overloaded welding cable can overheat and create a fire
hazard.

6. After completing operations, inspect the work area to

make certain there are no hot sparks or hot metal which
could cause a later fire. Use fire watchers when neces-
sary.

7. For additional information, refer to NFPA Standard 51B,

"Fire Prevention in Use of Cutting and Welding Pro-
cesses", available from the National Fire Protection Asso-
ciation, Batterymarch Park, Quincy, MA 02269.

ELECTRICAL SHOCK -- Contact with live
electrical parts and ground can cause
severe injury or death. DO NOT use AC
welding current in damp areas, if move-
ment is confined, or if there is danger of
falling.

1. Be sure the power source frame (chassis) is connected

to the ground system of the input power.

2. Connect the workpiece to a good electrical ground.
3. Connect the work cable to the workpiece. A poor or

missing connection can expose you or others to a fatal
shock.

4. Use well-maintained equipment. Replace worn or dam-

aged cables.

5. Keep everything dry, including clothing, work area, cables,

torch/electrode holder, and power source.

6. Make sure that all parts of your body are insulated from

work and from ground.

7. Do not stand directly on metal or the earth while working

in tight quarters or a damp area; stand on dry boards or
an insulating platform and wear rubber-soled shoes.

8. Put on dry, hole-free gloves before turning on the power.
9. Turn off the power before removing your gloves.

10. Refer to ANSI/ASC Standard Z49.1 (listed on next page)

for specific grounding recommendations. Do not mistake
the work lead for a ground cable.

ELECTRIC AND MAGNETIC FIELDS —
May be dangerous. Electric current flow-
ing through any conductor causes lo-
calized Electric and Magnetic Fields
(EMF). Welding and cutting current cre-
ates EMF around welding cables and
welding machines. Therefore:

1. Welders having pacemakers should consult  their physi-

cian before welding. EMF may interfere with some pace-
makers.

2. Exposure to EMF may have other health effects which are

unknown.

3. Welders should use the following procedures to minimize

exposure to EMF:
A. Route the electrode and work cables together. Secure

them with tape when possible.

B. Never coil the torch or work cable around your body.
C. Do not place your body between the torch and work

cables. Route cables on the same side of your body.

D. Connect the work cable to the workpiece as close as

possible to the area being welded.

E. Keep welding power source and cables as far away

from your body as possible.

Содержание 251cv

Страница 1: ...is equipment Do NOT attempt to install or operate this equipment until you have read and fully understand these Instructions If you do not fully understand these Instructions contact your supplier for further information Be sure this information reaches the operator You can get extra copies through your supplier This manual provides complete instructions for the following packages starting with Se...

Страница 2: ...wer Source 7 1 3 2 Optional Controls 7 1 4 Optional Accessories 7 1 4 1 MT 250SG Spool on Gun 7 1 4 2 ST 23A Spool On Gun Torch and Adaptor Kit 7 1 4 3 TR 24 and TR 251cv Trucks 7 1 4 4 Torch Wire Feed Accessories 7 1 5 Safety 7 1 6 Duty Cycle and Curves 7 1 7 Volt Ampere Curves 8 SECTION 2 INSTALLATION 9 2 1 Location 9 2 1 1 Lifting Eyebolt 9 2 2 Electrical Input Connections 9 2 2 1 Input Electri...

Страница 3: ...es on the workpiece which might pro duce flammable or toxic vapors Do not do hot work on closed containers They may explode 4 Have fire extinguishing equipment handy for instant use such as a garden hose water pail sand bucket or portable fire extinguisher Be sure you are trained in its use SAFETY PRECAUTIONS 11 95 5 Do not use equipment beyond its ratings For example overloaded welding cable can ...

Страница 4: ... Compressed Gas Association 1235 Jefferson Davis Highway Arlington VA 22202 EQUIPMENT MAINTENANCE Faulty or im properly maintained equipment can cause injury or death Therefore 1 Always have qualified personnel perform the installa tion troubleshooting and maintenance work Do not perform any electrical work unless you are qualified to perform such work 2 Before performing any maintenance work insi...

Страница 5: ...oigné de la zone de travail augmente en effet le risque de pas sage d un courant de sortie par des chaînes delevage PRÉCAUTIONS DE SÉCURITÉ AVERTISSEMENT Ces règles de sécurité ont pour objet d assurer votre protection Veillez à lire et à observer les précautions énoncées ci dessous avant de monter l équipement ou de commercer à l utiliser Tout défaut d observation de ces précautions risque d entr...

Страница 6: ...ticulières en matière de ventilation indiquées à l alinéa 6 de la norme Z49 1 de l AWS 5 ENTRETIEN DE L ÉQUIPEMENT Un équipement entretenu de façon défectueuse ou inadéquate risque non seulement de réaliser un travail de mauvaise qualité mais chose plus grave encore d entraîner des dommages corporels graves voire mortels en déclenchant des incendies ou des chocs électriques Observez par conséquent...

Страница 7: ...ry 10 This cycle can be repeated indefinitely See Figure 1 1 1 1 GENERAL This manual has been prepared especially for use in familiarizing personnel with the design installation op eration maintenance and troubleshooting of this equip ment All information presented here in should be given careful consideration to assure optimum performance of this equipment 1 2 RECEIVING HANDLING Prior to installi...

Страница 8: ...ight 20 9 inches 530 mm Width 12 9 inches 330 mm Depth 26 1 inches 660 mm Fig 1 1 Duty Cycle Curves Figure 1 2 Volt Ampere Curves DUTY CYCLE WELDING AMPERES 20 25 30 35 40 50 60 70 80 90 100 300 250 200 150 RATED OUTPUT VOLTS AMPS 1 7 VOLT AMPERE CURVES Figure 1 2 The Volt Ampere curves show the output voltage avail able at any given output current for the various Voltage Selector positions The ac...

Страница 9: ...nt of performance due to an overloaded circuit The primary input voltage requirements are noted on the unit s rating plate 2 1 LOCATION A proper installation site should be selected for the welding machine if the unit is to provide dependable service and remain relatively maintenance free A proper installation site permits freedom of air move ment into and out of the welding machine and also least...

Страница 10: ...eft side and the POSITIVE terminal is located on the right side The output cable connections will depend on the materials to be welded and on the welding process desired Table 2 2 provides the recommended cable output sizes Keep welding cables as short as possible Table 2 2 Output Cable Sizes Secondary Welding Total Length Feet of Current Cable in Weld Circuit 50 100 150 200 250 100 6 4 3 2 1 0 15...

Страница 11: ...ition output voltage is controlled by adjusting the voltage control knob on the front panel to the desired output In the Remote posi tion output is controlled at the wire feeder or remote control 3 1 4 VOLTAGE CONTROL This control allows the operator to adjust the output voltage Placing the Panel Remote switch in the Re mote position disables the voltage control on the front panel 3 1 5 FEEDER SEL...

Страница 12: ...reathing air DO NOT bring gas cylinders into confined spaces When leaving a confined space shut OFF gas supply at the source to prevent gas from leaking into thespace iftheswitchisaccidentlykeptdepressed Check the breathing atmosphere in the confined space to be sure it is safe to reenter E Never operate the equipment at currents greater than the rated ampere capacity Overheating will occur F Neve...

Страница 13: ...stat in the transformer windings which will open and prevent the contactor from closing if the transformer windings are overheated If the thermostat opens the ready light will go out Allow the equipment to idle with fan running until the light comes back on before attempting to weld again b Attempting to weld over grease or oil can cause weld defects c Before welding on aluminum be sure to clean s...

Страница 14: ...SECTION 3 OPERATION 14 Figure 3 2 Continuous Weld Conditions Figure 3 3 Angle of Welding Wire with Joint FILLET WELD BUTT WELD 45 90 10 10 TRAVEL TRAVEL ...

Страница 15: ...y by blowing it out with compressed air This cleaning operation is necessary so that maximum cooling will be accomplished by the air stream This should be done periodically depending upon the location of the unit and the amount of dust and dirt in the atmosphere The hermetically sealed silicon rectifiers are specially designed for welding machine use and will not age or deteriorate in use The diod...

Страница 16: ...s B Isolate trouble to one part of the welding installation primarypowersupply powersource Feederorwire guidetrain casing driverolls linersandcontacttip If this inspection indicates trouble in the Feeder use Troubleshooting Guide in the feeder manual Many troubleshooting situations require that the power remain On and that power terminals in the equipment carry voltage Exercise extreme caution whe...

Страница 17: ...ctions c Wrong polarity c Check for correct polarity 5 Welding output Voltage a Low line Voltage a Use correct voltage and or current too low b Welding cables too long or too b Use correct cable size small c Loose connection c Check all welding cable connections d Defective capacitor bank d Check capacitors for low leakage resistance 6 Stringy irregular bead a Torch moved too fast a Move torch slo...

Страница 18: ...lls or replace 13 Wire does not feed motor a Kink etc in wire or wire bound a Straighten or feed wire until running drive roll turns on reel clear and cut off b Wire freezing to contact tip b Free freeze or remove contact burnback tip feed wire until clear cut end free and replace tip c Clogged liner c Replace liner 14 Wire does not feed a Motor a With wire speed dial on 700 motor NOT running pres...

Страница 19: ...19 D 37309 B Figure 5 1 Schematic Diagram 251cv Power Source All Models ...

Страница 20: ...20 D 37310 B Figure 5 2 Wiring Diagram 251cv Power Source All Models ...

Страница 21: ... warranty Replacement parts may be ordered from your ESAB distributor or from ESAB Welding Cutting Products Attn Customer Service Dept PO Box 100545 Ebenezer Road Florence SC 29501 0545 Be sure to indicate any special shipping instructions when ordering replacement parts To order parts by phone contact ESAB at 1 843 664 5540 Orders may also be faxed to 1 800 634 7548 Be sure to indicate any specia...

Страница 22: ...22 SECTION 6 REPLACEMENT PARTS Figure 6 1 251cv Power Source Front View 2 1 16 4 3 17 5 6 7 8 9 10 11 19 18 12 13 3 14 15 20 Male Plug not shown 21 Eye Bolt not shown ...

Страница 23: ...d 10 1 13730632 Potentiometer 10K 2W R1 11 1 37306YL Cover Top 12 1 34141GY Cover Option optional Meter Kit shown 13 1 952206 Light Indicator 28V White PL1 14 2 2062161 Circuit Breaker 5A CB1 2 15 1 36107 Switch Power 600V 63A with knob S3 16 1 954008 Label Danger High Voltage 17 2 13734588 Logo ESAB Clear 18 1 2091514 Label Warning 19 1 954747 Label Schematic Inside Top Cover 20 2 13733936 Quick ...

Страница 24: ...24 SECTION 6 REPLACEMENT PARTS 33 32 41 42 35 36 37 39 38 34 31 Figure 6 2 251cv Power Source Right Side View 40 43 44 45 ...

Страница 25: ...3730583 Term Bushing 687 37 1 952683 Fuse Solid State F2 38 1 32261 Board Term Input 200 230 460 V TB1 1 32265 Board Term Input 230 460 575 V TB1 1 32266 Board Term Input 220 400 V TB1 39 2 or 3 672065 Strap Terminal 40 1 36800GY Fan Bracket 41 1 37304GY Rear Panel 42 1 954743 Label Rating 200 230 460 V 1 954744 Label Rating 230 460 575 V 1 954745 Label Rating 220 400 V 43 1 950711 Switch Thermal ...

Страница 26: ...26 SECTION 6 REPLACEMENT PARTS 52 54 53 63 62 55 56 57 58 59 64 Figure 6 3 251cv Power Source Left Side View 51 65 60 61 Bottom of 58 ...

Страница 27: ... Pos TB2 56 1 950760 Relay Enclosed DPDT 24V 10A K1 57 1 23604891 Label High Voltage Warning 58 1 952566 Heatsink SCR 59 2 952564 SCR 180A SCR1 2 60 1 950710 Switch Thermal 130 F not shown front TS4 61 1 950711 Switch Thermal 194 F not shown rear TS1 62 1 36806 Bus Cap Pos 63 1 17250200 Resistor 20 Ohm 50W R3 64 1 36810 Cable Power Input 65 1 97W63 Connector Cable Grip Parts List for Figure 6 3 25...

Страница 28: ...air Stations C TECHNICAL SERVICE Telephone 800 ESAB 123 Fax 843 664 4452 Part Numbers Technical Applications Hours 8 00 AM to 5 00 PM EST Performance Features Technical Specifications Equipment Recommendations D LITERATURE REQUESTS Telephone 843 664 5501 Fax 843 664 5548 Hours 7 30 AM to 4 00 PM EST E WELDING EQUIPMENT REPAIRS Telephone 843 664 4469 Fax 843 664 5557 Repair Estimates Repair Status ...

Отзывы: