≥8°
Sleeve
Shield
59
≥
500mm
4. Installation Walkthrough
4.4. Outdoor Unit Installation
4.4.2. Installation Process
For the installation, users can either use the dedicated mounting bracket provided by the supplier, or
prepare a suitable bracket that meets the following requirements.
1) The unit must be supported by either flat concrete blocks, or a dedicated mounting bracket.
The bracket should be able to support at least 5x the unit’s weight.
After the bracket is fixed, ensure each of the nuts are fully tightened.
Users should double check to make sure the unit’s installation is sufficiently sturdy.
The bracket material can be stainless or galvanized steel, aluminum, or other proper substitutes.
The user can opt to use two concrete blocks, or a raised concrete platform, instead of a
dedicated mounting bracket. Ensure that the unit is securely fastened after installation.
Use the oudoor unit’s dimensions when choosing a suitable wall bracket.
2)
3)
4)
5)
6)
The platform must be at least 500 mm above ground.
。
Holes for piping kits should be raised at least 8
This ensures rain water/condensate does not flow back indoors.