32
3BA00068 • 2016-03-07 • Rev. 3
ersa RA 4500
Functional description
5.2.2
Description of the flow chart
Starting from the actual value display, the next menu point in each case is reached via
the ENTER key. The sequence of menu items (parameter settings) is shown in the flow
chart in Figure 3. Each parameter setting is entered using the (+) and (-) keys. You can
jump back to the actual value display from any menu item by double-clicking (pressing
twice) the ENTER key.
The symbol for the given menu item flashes in the fourth position. If no input is made
within 8 seconds, the station returns to the actual value display. All parameter settings
are saved and take effect immediately.
5.2.3
Abbreviated Procedure
The double-click feature has been integrated for easier parameter setting. Once you have
carried out a parameter setting within the flow chart (see Figure 3), you can return to the
actual value display by double-clicking (pressing twice) the ENTER key. By again double-
clicking in the actual value display, you can now branch off from the menu item last
selected; you need not run through the entire menu.
5.3
Description of the features
5.3.1
Setpoint feature (
�
)
The desired temperature setpoint is set in the first menu item (see flow chart in Figure 4)
by means of the (+) and (-) keys. The different solder baths or heating plates have differ
-
ent temperature ranges, which are shown in the corresponding operating instructions.
Note:
The given setpoint can be automatically decreased with the correspond
-
ing calibration setting (see section 5.3.5 on the Calibration Feature)