Installation Manual
MAINTENANCE AND DIAGNOSIS OF FAILURES
1
MAINTENANCE
Before carrying out any maintenance
operation, disconnect the device from the
power supply.
O
If you have to dismount the operator from its
supports, first tighten the discharge screw in
order to prevent the hydraulic fluid from
leaking.
1
Regularly check the installation in order to discover
any imbalance or signs of deterioration or wear. Do
not use the device if any repair or adjustment is
necessary.
2
Clean and lubricate the articulations of the gate, so
as not to increase the effort of the operator.
3
Check that the controls and photocells, as well as
their installation, have not suffered any damage
from the weather or external agents.
2
FAILURE DIAGNOSIS
Problem
Cause
Solution
The operator does not make any
movement when the opening or
closing key devices are activated
Absence of system power supply
voltage
Restore the power supply
Electrical installation defective
Check that the installation does
not present any short-circuits or
cut-off points
Defective control board or control
devices
Check these elements, using their
respective manuals
Defective capacitor
Check the state of the capacitor
When using the opening or closing
key devices, the operator is
activated but the gate does not
move
The assembly levels of the supports
have not been respected.
Dismount the supports and then
put them back in place, respecting
the assembly levels
The screw for manual operation is
in unlock position
Using the corresponding wrench,
position the screw in "automatic
operation lock" position.
The gate moves in an irregular
manner
The operator is not horizontal
Remove the support pieces and
mount them again, ensuring the
operator is horizontal
The operator does not make a soft
stop (no slow down)
The spindle does not reach the limit
switch
Move the front support
The gate cannot completely close
(or open)
The photocell detects an obstacle
Remove the obstacle and try again
The resistance of the gate has
increased when closing (or when
opening)
Check the moving parts of the gate
and remove the resistance
The thrust of the operator during
closing (or opening) is too low
Use the opening and closing
pressure adjustment screws to
increase the thrust when opening
or closing
The assembly levels of the supports
have not been respected.
Dismount the supports and then
put them back in place, respecting
the assembly levels
Содержание VULCAN D VUA12
Страница 2: ......
Страница 24: ...Actualizado 22 1 13 MANTENIMIENTO Y DIAGNÓSTICO DE AVERÍAS 20 Manual de instalación ...
Страница 44: ...Mis à jour 25 2 13 MAINTENANCE ET DIAGNOSTIC DE PANNES 40 Manuel d installation ...
Страница 64: ...Updated 21 2 13 MAINTENANCE AND DIAGNOSIS OF FAILURES 60 Installation Manual ...
Страница 84: ...Actualizado 21 2 13 MANUTENÇÃO E DIAGNÓSTICO DE AVARIAS 80 Manual de instalação ...