GENERAL FEATURES OF THE OPERATOR
The VULCAN D (residential) operator is constructed to
form part of a swing gate automation system. The
requirements set out in Standard EN 12453 can be
complied with by installing the corresponding safety
items.
It comprises a metal body, which contains a hydraulic
pump and a drive piston.
VUA Models (with slow down)
The VUA models have a slow-down system in the
spindle, meaning the speed slows down when
approaching the end of the extension run (closing run
when the operator is installed for inward opening),
ending in a soft stop.
3
MAIN OPERATOR PARTS
Fig. 2
VULCAN D Operator main parts
C240A
1
Supports
2
Support shafts
3
Spindle
4
Spindle cover
5
Closing pressure adjustment screw
6
Opening pressure adjustment screw
7
Unlocking screw
8
Electrical connections cover
9
Discharge screw