DigiOpG2
Digital Video Recorder
Page
12
3040-00052
2.3.1.
Camera
Connect BNC plug of camera video cable into the desired BNC input.
Note
Camera input voltage level is 1Vp-p±10%.
2.3.2.
LOOP OUT
Use to apply the video of camera input to other device. Without using a video distributor, the same image can be connected
to the camera input of other product.
2.3.3.
MON OUT
Connect the BNC cable of the monitor to MON OUT BNC cable of the rear panel.
2.3.4.
SPOT OUT
The spot monitor can only be used to display input images in automatic interval mode. Refer to “Settings” for automatic
interval time setting of spot monitor.
2.3.5.
Power Input
Connect to main power cord of the system.
Caution
Before plugging-in the power cord to the system, check if the power is in accordance with the system
specification (Single Phase AC 115~230V)
2.3.6.
Select NTSC / PAL
Turn off the power of the EDNS-3000 series and select the NTSC/PAL switch correctly. Then turn on the power again.
2.3.7.
SENSOR Input
Connect sensor (dry contact type). Separate the terminal block and wire all devices to desired pins, before connecting the terminal
block again. Connect each ground (GND) line to “G” pins.
Note
Support both N/O (Normal Open) and N/C (Normal Close). If connected sensor is not functioning, ensure wiring is
correct.
2.3.8.
USB Port
Connect USB storage device.
Note
Refer to “Image Backup” for details on the supported USB storage device of EDNS-3000.
2.3.9.
LAN Port
Connect RJ-45 jack of LAN cable to LAN port. Network has to be TCP/IP base 10/100BASE-TX Ethernet LAN (Local Area
Network), Internet or exclusive line, and IP address should be fixed one. Consult network administrator for proper network
configuration.
2.3.10.
S-Video Output
One additional main monitor can be installed by using the S-Video output. Use the S-Video cable to connect the EDNS-3000
with the monitor, which has S-Video Input.
2.3.11.
Serial Port
Port for RS-232 signal output.
2.3.12.
Audio Out
Connect audio output equipment.
Note
Use of audio output device with an amplifier is recommended
2.3.13.
Audio In
Connect Audio Input device.
Note
Input voltage of audio input device is line level.
Use of audio output device with amplifier is recommended.
2.3.14.
Alarm Out / P/T/Z
Connect various alarm devices controlled by relay output. EDNS-3000 series supports RS-485 for P/T/Z control.