among them:
NO=2 PLLDO
1M<XTAL/ PLLN<25MHz;
200MHz<CLK×NO<1000MHz;
PLLM>1;PLLN>1;
By setting bit 7 of the 0x0C register to 1, the PLL can be bypassed. At this time, the PLL output is
CLK=XTALI;
Configure bit 0 of 0x0C to 1 or the PWD pin of the chip is pulled high to put the PLL into sleep
state. At this time, the PLL has no clock output.
Configure bit 7 (Clk_in_sel) of Register 0x0A as 1, and CLK does not select the output clock of the
PLL. Instead, choose XTALI directly, which is CLK=XTALI.
Table 4.1 recommends two typical PLL output clock configuration parameters
XTALI
PLL configuration
parameters
PLL output
clock
System clock
configuration
parameter
System output clock
12.288M
Reg0x0B = 0x40
Reg0x0C = 0x32
49.152M
Reg0xB9 = 0x05
Reg0xBA = 0x04
Reg0xBB = 0x02
Sys_clk=9.8304
Clk_codec=12.288M
CLKOUT=24.576M
29.4912M
Reg0x0B = 0x28
Reg0x0C = 0x33
49.152M
Reg0xB9 = 0x05
Reg0xBA = 0x04
Reg0xBB = 0x02
Sys_clk=9.8304
Clk_codec=12.288M
CLKOUT=24.576M
4.4 Chip parameter configuration interface
The MCU uses the U_SPI port to perform parameter configuration, status control information, and
write/receive data to and from the HR_C6000, and performs corresponding interrupt processing
according to the TIME_SLOT_INTER, SYS_INTER, RF_TX_INTER, and RF_RX_INTER
interrupts given by the HR_C6000. The MCU can also control the Sleep state of the chip through
the GPIO pins. Its interface is shown below.