Glossary
12.2
Major Severity Alarms
12.2.1
ElnOverheat
MIB:
ERICSSONELNTRAPMIB
Description
: A temperature has exceeded the temperature limit in the switch.
The reason can be fan failure, too high ambient temperature or both.
Corrective Actions
:
Ensure that the ambient temperature is within the specified operating range.
Check that the fan is working and the air inlets and outlets for the fans are
not blocked.
Valid from EDA 2.2 R3A
Parameters:
No. Parameter
Parameter Value
1
Managed object
class
EFN324f
or
ELN220
2
Managed object
Instance
EFN324=<
IP address
>
or
ELN220=<
IP address
>
3
Sequence number
Alarm sequence number
4
Perceived severity
Major
5
Event time
Time stamp from real time clock, retrieved
through a SNTP server
6
Event type
equipmentAlarm
7
Probable cause
temperatureUnacceptable
8
Temperature Value
The temperature of the node
9
Temperature Limit
The temperature threshold value
Clearing Alarms
ElnOverheatOK, ElnRestart
Содержание EFN324
Страница 1: ...EFN324 User Guide EDA 1200...
Страница 4: ...Error No text of specified style in document Glossary 168 Index 170...
Страница 176: ......