5.1 CONDITIONS FOR THE CORRECT 

 WORKING OF THE EQUIPMENT

•   Do not use hot water in the system 

(T>35ºC).

•   

The ambient temperature must be 
between 4 ºC and 35 ºC.

•   The system should be installed in a 

dry environment, free of acid vapours. 
Otherwise, please ensure a proper 
ventilation.

•   Water to be treated must be properly 

filtered, therefore, it is recommended 
that a pre-filter is installed to guarantee 
the removal of suspended particles, 
which may be swept along by inlet 
water.

Failure to install an appropriate 
filter would result in particles 

obstructing the inner holes or injectors 
of the system, thus affecting its proper 
operation. 

•   A minimum pressure of 2.5 bars must 

be ensured. Should this minimum 
pressure not be available, a pressure 
system must be installed.

•   If inlet pressure is higher than 5.5 bars, 

a pressure regulator must be installed.

5.2 INSTALLATION OF THE SYSTEM

If the water softener must treat the whole 
water supply, connect it to the general 
supply pipe before connecting the rest 
of the pipes, except for pipes supplying 
the outside. Taps located outside the 
house must supply hard water. Due to 
the sodium increase in softened water, 
it is not recommended to use it for 
watering, since it can negatively affect 
the growth of plants and vegetables.

In the event of modifying the home/
workplace in order to install the 
equipment in the planned location, 
it should be done following national 
guidelines for interior installations of 
water and electric supply.

The installation location should have 
sufficient space for the machine itself, its 
accessories, connections and room for 

servicing and repair. The system should 
not be installed next to a heat source or 
where it receives a direct flow of hot air.

The drain connection, where water from 
regeneration will be driven, must be 
underneath the installation if possible. 
The drain connection must always 
have a free outlet. The diameter of this 
connection must have a minimum size 
of 1”. The maximum distance between 
the water softener and the drain intake 
cannot be higher than 6m.

Drain pipe

Drain pipe

Drain pipe

Subterranean drainage

Feed pipe

Sink outlet

4 cm

aeration

4 cm

aeration

Raising the drain intake above the water 
softener level is not recommended, since 
it can affect the brine suction and, thus, 
impair the regeneration process.

In the event that this is deemed essential, 
it can be raised a maximum of 1.5m, 
provided that the inlet pressure is higher 
than 4 bar.

If the height is greater or there is 
not enough pressure, contact your 
distributor. Under no circumstances 
should the equipment be 

 

installed outdoors. The environment 
where the equipment is to be installed 
should adhere to any appropriate 
hygiene and sanitation conditions.

Avoid any external dripping liquids 
from pipes, wastewater, etc. onto the 
equipment.

Should softened water be supplied to a 
hot water or vapour generator, it will be 
necessary to install a dependable check 
valve between the water softener and 
the generator, in order to prevent hot 
water from returning to the system and 
damaging it.

The existing pipelines must not have 
deposits of either iron or limescale. 
Replace all pipelines containing a great 
amount of iron or limescale deposits. 

Содержание ERGO 11

Страница 1: ...Water Softener User Manual Adoucisseur d eau Guide d utilisation www puricom eu ENG FR...

Страница 2: ...l ctrica ausencia de programaci n y de problemas REGENERACI N ULTRA R PIDA Lavados completos en 15 minutos BAJO CONSUMO Regeneraciones m s eficientes V LVULA MEZCLADORA Permite regular el grado de dur...

Страница 3: ...____________________________ 17 12 Service Book User_________________________________________ 18 ENG FR SOMMAIRE 1 Pr sentation_______________________________________________ 20 2 Introduction________...

Страница 4: ...in this manual This is the symbol for a safety alert This symbol will warn you about possible situations in which you or those around you could be at risk All safety messages will have the alert symbo...

Страница 5: ...e most common measurements to follow UNITS ppm of CaCO3 French 1 ppm of Calcium 2 5 0 25 1 ppm of Magnesium 4 13 0 413 1 ppm of CaCO3 1 0 1 1 French HF 10 1 1 German d 17 8 1 78 1 English e 14 3 1 43...

Страница 6: ...nters the central tube through the lower distributor Following this the brine flows towards the drain tube through the drain valve The resin beads are replaced by sodium ions from the brine solution d...

Страница 7: ...7 NOTE For human consumption water it is recommended in most cases to have a residual hardness between 5 and 8 HF if pipes are made of copper and between 8 and 10 HF if they are made of iron for the...

Страница 8: ...l connection NA Rated eletrical power NA Protection class NA Dimensions h x d x w 506 x 293 x 498 608 x 298 x 501 Setting of the hardness regulator ERGO 8 ERGO 11 Letter Hardness Letter Hardness ppm d...

Страница 9: ...at can be recycled and reused This product must not be thrown away into the usual urban rubbish bins When you wish to dispose of the machine it must be taken to a specific centre for the collection of...

Страница 10: ...ocation should have sufficient space for the machine itself its accessories connections and room for servicing and repair The system should not be installed next to a heat source or where it receives...

Страница 11: ...s for a prolonged period of time use adequate safety devices Note We recommend that the installation is carried out by a qualified installer Failure to install the equipment in accordance with this ma...

Страница 12: ...d in order to prevent any damage DANGER There is a danger of injury due to an excess of weight It is necessary that at least two people move and install the system as well as move and rise the salt ba...

Страница 13: ...nufacturer when using other types of pipes and fixtures approved for drinking water 6 2 INSTALLATION OF THE DRAIN AND THE OVERFLOW Take the drain tubes towards the discharge point Connect the 1 2 tube...

Страница 14: ...e system with salt until the end of the start up In order to prevent any air pressure on the water softener and the pipes please follow these instructions in order 1 Keep the by pass valve in the by p...

Страница 15: ...desired values Otherwise adjust the regulator and check again 3 4 WARNING The hardness regulator is supplied in the closed position therefore if the system is not adjusted it will supply fully softene...

Страница 16: ...ance from the floor up to the salt edge Then put the tool in the salt If there is a hard object it may be a salt bridge Carefully apply some pressure on several places until it breaks Press Tool Press...

Страница 17: ...not automatically move to the next regeneration please contact your distributor to receive further assistance I can hear my equipment running or carrying out the regeneration during daytime My previou...

Страница 18: ...YPE OF SERVICE DATE NAME SIGNATURE AND STAMP OF AUTHORISED TECHNICIAN MAINTENANCE COMPLETE REPAIR SANITATION OTHERS INITIAL OPERATION TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINA...

Страница 19: ...N OTHERS TYPE OF SERVICE DATE NAME SIGNATURE AND STAMP OF AUTHORISED TECHNICIAN MAINTENANCE COMPLETE REPAIR SANITATION OTHERS INITIAL OPERATION TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNIC...

Страница 20: ...vous avertit des situations dans lesquelles vous ou votre entourage courez un risque potentiel Tous les messages de s curit seront accompagn s d un symbole d alerte ou du mot DANGER ou ATTENTION Port...

Страница 21: ...s en fonction des r gions Les unit s les plus communes sont indiqu es ci apr s UNIT S ppm Degr de CaCO3 fran ais 1 ppm de calcium 2 5 0 25 1 ppm de magn sium 4 13 0 413 1 ppm de CaCO3 1 0 1 1 degr fra...

Страница 22: ...ia le diffuseur inf rieur Ensuite la saumure s coule dans le tuyau d vacuation travers la vanne d vacuation Les billes de r sine sont r g n r es par les ions de sodium de la saumure lors des tapes de...

Страница 23: ...la plupart des cas la duret r siduelle recommand e est comprise entre 5 et 8 fH pour des canalisations en cuivre et entre 8 et 10 fH pour des canalisations en fer pour ces derni res l installation ul...

Страница 24: ...5 bar D bit minimum 0 17m3 h Pression nominale 8 6 bar Raccordement lectrique NA Puissance nominale NA Class de protection NA Dimensions h x d x w 506 x 293 x 498 608 x 298 x 501 R glage du r gulateur...

Страница 25: ...vant tre recycl s et r utilis s Ce produit ne doit pas tre jet avec vos ordures m nag res habituelles Lorsque vous d sirez jeter la machine elle doit tre emmen e dans un centre sp cifique de collecte...

Страница 26: ...re suffisamment spacieux pour la machine en elle m me ses accessoires raccordements et les op rations d entretien et de r paration Le syst me ne doit pas tre install c t d une source de chaleur ou un...

Страница 27: ...flamme du pistolet souder ou d une augmentation excessive de la temp rature N utilisez jamais de PLOMB avec votre pistolet souder 5 Mise la terre Lors de l installation d un tuyau en plastique entre d...

Страница 28: ...le haut ou vers le bas Les raccords destin s la t te de commande doivent tre correctement branch s sur l entr e et la sortie et disposent de rep res en relief 1 Le syst me doit toujours tre install a...

Страница 29: ...tous les raccords filet s TUYAU EN PLASTIQUE CPVC 1 Nettoyez pr parez et collez toutes les jointures conform ment aux instructions du fabriquant AUTRE Veuillez suivre les instructions du fabriquant d...

Страница 30: ...ur l activateur de r g n ration de l adoucisseur d eau et tournez le doucement dans le sens des aiguilles d une montre jusqu entendre 4 clics afin de lancer la r g n ration ce stade on doit entendre d...

Страница 31: ...e sel descende lors des premi res minutes de la r g n ration Cela signifie que le processus d aspiration de la saumure fonctionne correctement Laissez la r g n ration se terminer ATTENTION il est capi...

Страница 32: ...NE METTEZ JAMAIS DE SEL GEMME OU DE SEL FIN dans votre syst me Ils contiennent des impuret s susceptibles de nuire aux performances et de rendre nulle la garantie limit e Comment casser un pont de sel...

Страница 33: ...mon appareil se r g n re correctement V rifiez que l alimentation en eau vers l adoucisseur n est pas d riv e par un by pass Suivez les instructions de la page 14 pour r g n rer manuellement les r se...

Страница 34: ...GNATURE ET CACHET DU TECHNICIEN AGR PREMI RE INTERVENTION TECHNICIEN NORMAL EXTRAORDINAIRE GARANTIE MAINTENANCE COMPL TE CACHET R PARATION ASSAINISSEMENT AUTRES PREMI RE INTERVENTION TECHNICIEN NORMAL...

Страница 35: ...DU TECHNICIEN AGR PREMI RE INTERVENTION TECHNICIEN NORMAL EXTRAORDINAIRE GARANTIE MAINTENANCE COMPL TE CACHET R PARATION ASSAINISSEMENT AUTRES PREMI RE INTERVENTION TECHNICIEN NORMAL EXTRAORDINAIRE G...

Страница 36: ...www puricom eu...

Отзывы: