Erbauer ERB596CSW Скачать руководство пользователя страница 6

c. Disconnect the plug from the power source and/or 
the battery pack from the power tool before making any 
adjustments, changing accessories, or storing power tools.

 

Such preventive safety measures reduce the risk of starting the 

power tool accidentally. 

d. Store idle power tools out of the reach of children and 
do not allow persons unfamiliar with the power tool or 
these instructions to operate the power tool.

 Power tools are 

dangerous in the hands of untrained users. 

e. Maintain power tools. Check for misalignment or binding 
of moving parts, breakage of parts and any other condition 
that may affect the power tool’s operation. If damaged, 
have the power tool repaired before use.

 Many accidents are 

caused by poorly maintained power tools. 

f. Keep cutting tools sharp and clean.

 Properly maintained 

cutting tools with sharp cutting edges are less likely to bind and 
are easier to control. 

g. Use the power tool, accessories and tool bits etc. in 
accordance with these instructions, taking into account the 
working conditions and the work to be performed.

 Use of 

the power tool for operations different from those intended could 

result in a hazardous situation. 

5. Service

a. Have your power tool serviced by a qualiied repair person 

using only identical replacement parts.

 This will ensure that 

the safety of the power tool is maintained.

ADDITIONAL SAFETY RULES FOR YOUR CIRCULAR SAW

1.  Always wear a dust mask, hearing protection and eye 

protection.

2.  Only use saw blades recommended in the speciication.

3.  Do not use any abrasive wheels.

4.  Use only blade diameter(s) in accordance with the markings.

5.  Always wear gloves when handling saw blades and rough 

material. Saw blades shall be carried in a holder whenever 

practicable.

Содержание ERB596CSW

Страница 1: ...2000W 235mm CIRCULAR SAW ERB596CSW ERB596CSW...

Страница 2: ...Original Instructions Version 1 0...

Страница 3: ...se of the goods This guarantee does not affect your statutory rights This guarantee is only valid in the UK For further technical advice spare parts or repair service outside of guarantee please conta...

Страница 4: ...er modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodiied plugs and matching outlets will reduce risk of electric shock b Avoid body contact with earthed o...

Страница 5: ...ve any adjusting key or wrench before turning the power tool on A wrench or a key left attached to a rotating part of the power tool may result in personal injury e Do not overreach Keep proper footin...

Страница 6: ...ols sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control g Use the power tool accessories and tool bits etc in accordance with t...

Страница 7: ...ade from high speed steel HSS 13 Always check walls loors and ceilings to avoid hidden power cable and pipes 14 Do not cut material containing asbestos 15 Do not use circular saw to cut tree limbs or...

Страница 8: ...HER SAFETY INSTRUCTIONS FOR CIRCULAR SAWS KICKBACK CAUSES AND RELATED WARNINGS Kickback is a sudden reaction to a pinched bound or misaligned saw blade causing an uncontrolled saw to lift up and out o...

Страница 9: ...use dull or damaged blades Unsharpened or improperly set blades produce narrow kerf causing excessive friction blade binding and kickback f Blade depth and bevel adjusting locking levers must be tigh...

Страница 10: ...ine dust also known as Respirable Crystalline Silica or RCS during many common tasks such as cutting drilling and grinding Breathing in very ine particles of crystalline silica can lead to the develop...

Страница 11: ...med decisions as to the period of time a power tool can be used safely on a daily basis and the choice of tool Further Advice can be found at www hse gov uk Vibration total values triax vector sum det...

Страница 12: ...ades Maintain this tool in accordance with these instructions and keep well lubricated where appropriate Avoid using tools in temperatures of 10 C or less Plan your work schedule to spread any high vi...

Страница 13: ...Wear ear protection Wear eye protection Wear dust mask Wear gloves Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local...

Страница 14: ...1 2 3 4 7 5 6 8 9 10 11 12 13 14 15 17 16 18 19...

Страница 15: ...O MARK 8 0O MARK 9 PARALLEL GUIDE 10 FIXED GUARD 11 SAW BLADE 12 LOWER BLADE GUARD 13 LOWER GUARD LEVER 14 BASE PLATE 15 DUST TUBE 16 LOCK OFF BUTTON 17 SPINDLE LOCK BUTTON 18 DEPTH OF CUT SCALE 19 DE...

Страница 16: ...Machine weight 85mm 65mm II 6 8kg NOISE INFORMATION A weighted sound pressure LpA 97dB A KPA 3 0dB A A weighted sound power LwA 108dB A KWA 3 0dB A Wear ear protection when sound pressure is over 80d...

Страница 17: ...terclockwise direction 3 Completely remove blade bolt 21 and remove outer lange 22 The part remaining is the inner lange 23 and does not need to be removed 4 Rotate the lower guard using the lower gua...

Страница 18: ...rating The right and wrong ways to support large work pieces are shown in Fig 3 1 and Fig 3 2 DEPTH OF CUT ADJUSTMENT See Fig 4 1 4 2 Lift up the depth adjustment lever 19 to loose it Hold the base pl...

Страница 19: ...d for accurate work to set the angle with a protractor and make a test cut on other material Do not use the depth of cut scale when making bevel cuts due to possible inaccuracy PARALLEL GUIDE ADJUSTME...

Страница 20: ...socket before carrying out any adjustment servicing or maintenance Your power tool requires no additional lubrication or maintenance There are no user serviceable parts in your power tool Never use w...

Страница 21: ...as follows The wire which is coloured blue must be connected to the terminal which is marked with N The wire which is coloured brown must be connected to the terminal which is marked with L Warning Ne...

Страница 22: ...of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment 2011 65 EU Waste Electrical and Electronic Equipment WEEE 2012 19 EU Standards and technical speciications referred t...

Страница 23: ......

Страница 24: ......

Отзывы: