Erbauer ERB596CSW Скачать руководство пользователя страница 4

GENERAL POWER TOOL SAFETY WARNINGS

   

Warning: Read all safety warnings and all instructions. 

Failure to follow the warnings and instructions may result in 

electric shock, ire and/or serious injury.

        

Save all warnings and instructions for future reference.

The term “power tool” in the warnings refers to your electric (corded) 

power tool or battery-operated (cordless) power tool.

1.  Work area safety

a. Keep work area clean and well lit.

 Cluttered or dark areas 

invite accidents.

b. Do not operate power tools in explosive atmospheres, 

such as in the presence of lammable liquids, gases or dust. 

Power tools create sparks which may ignite the dust or fumes.

c. Keep children and bystanders away while operating a 
power tool.

 Distractions can cause you to lose control.

2.  Electrical safety

a. Power tool plugs must match the outlet. Never modify the 
plug in any way. Do not use any adapter plugs with earthed 
(grounded) power tools.

 Unmodiied plugs and matching outlets 

will reduce risk of electric shock.

b. Avoid body contact with earthed or grounded surfaces, 
such as pipes, radiators, ranges and refrigerators. 

There 

is an increased risk of electric shock if your body is earthed or 
grounded.

c. Do not expose power tools to rain or wet conditions.

 Water 

entering a power tool will increase the risk of electric shock.

d. Do not abuse the cord. Never use the cord for carrying, 
pulling or unplugging the power tool. Keep cord away from 
heat, oil, sharp edges or moving parts. 

Damaged or entangled 

cords increase the risk of electric shock.

e. When operating a power tool outdoors, use an extension 
cord suitable for outdoor use. 

Use of a cord suitable for outdoor 

use reduces the risk of electric shock. 

f. If operating a power tool in a damp location is unavoidable, 
use a residual current device (RCD) protected supply.

 Use of 

an RCD reduces the risk of electric shock.

Содержание ERB596CSW

Страница 1: ...2000W 235mm CIRCULAR SAW ERB596CSW ERB596CSW...

Страница 2: ...Original Instructions Version 1 0...

Страница 3: ...se of the goods This guarantee does not affect your statutory rights This guarantee is only valid in the UK For further technical advice spare parts or repair service outside of guarantee please conta...

Страница 4: ...er modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodiied plugs and matching outlets will reduce risk of electric shock b Avoid body contact with earthed o...

Страница 5: ...ve any adjusting key or wrench before turning the power tool on A wrench or a key left attached to a rotating part of the power tool may result in personal injury e Do not overreach Keep proper footin...

Страница 6: ...ols sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control g Use the power tool accessories and tool bits etc in accordance with t...

Страница 7: ...ade from high speed steel HSS 13 Always check walls loors and ceilings to avoid hidden power cable and pipes 14 Do not cut material containing asbestos 15 Do not use circular saw to cut tree limbs or...

Страница 8: ...HER SAFETY INSTRUCTIONS FOR CIRCULAR SAWS KICKBACK CAUSES AND RELATED WARNINGS Kickback is a sudden reaction to a pinched bound or misaligned saw blade causing an uncontrolled saw to lift up and out o...

Страница 9: ...use dull or damaged blades Unsharpened or improperly set blades produce narrow kerf causing excessive friction blade binding and kickback f Blade depth and bevel adjusting locking levers must be tigh...

Страница 10: ...ine dust also known as Respirable Crystalline Silica or RCS during many common tasks such as cutting drilling and grinding Breathing in very ine particles of crystalline silica can lead to the develop...

Страница 11: ...med decisions as to the period of time a power tool can be used safely on a daily basis and the choice of tool Further Advice can be found at www hse gov uk Vibration total values triax vector sum det...

Страница 12: ...ades Maintain this tool in accordance with these instructions and keep well lubricated where appropriate Avoid using tools in temperatures of 10 C or less Plan your work schedule to spread any high vi...

Страница 13: ...Wear ear protection Wear eye protection Wear dust mask Wear gloves Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local...

Страница 14: ...1 2 3 4 7 5 6 8 9 10 11 12 13 14 15 17 16 18 19...

Страница 15: ...O MARK 8 0O MARK 9 PARALLEL GUIDE 10 FIXED GUARD 11 SAW BLADE 12 LOWER BLADE GUARD 13 LOWER GUARD LEVER 14 BASE PLATE 15 DUST TUBE 16 LOCK OFF BUTTON 17 SPINDLE LOCK BUTTON 18 DEPTH OF CUT SCALE 19 DE...

Страница 16: ...Machine weight 85mm 65mm II 6 8kg NOISE INFORMATION A weighted sound pressure LpA 97dB A KPA 3 0dB A A weighted sound power LwA 108dB A KWA 3 0dB A Wear ear protection when sound pressure is over 80d...

Страница 17: ...terclockwise direction 3 Completely remove blade bolt 21 and remove outer lange 22 The part remaining is the inner lange 23 and does not need to be removed 4 Rotate the lower guard using the lower gua...

Страница 18: ...rating The right and wrong ways to support large work pieces are shown in Fig 3 1 and Fig 3 2 DEPTH OF CUT ADJUSTMENT See Fig 4 1 4 2 Lift up the depth adjustment lever 19 to loose it Hold the base pl...

Страница 19: ...d for accurate work to set the angle with a protractor and make a test cut on other material Do not use the depth of cut scale when making bevel cuts due to possible inaccuracy PARALLEL GUIDE ADJUSTME...

Страница 20: ...socket before carrying out any adjustment servicing or maintenance Your power tool requires no additional lubrication or maintenance There are no user serviceable parts in your power tool Never use w...

Страница 21: ...as follows The wire which is coloured blue must be connected to the terminal which is marked with N The wire which is coloured brown must be connected to the terminal which is marked with L Warning Ne...

Страница 22: ...of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment 2011 65 EU Waste Electrical and Electronic Equipment WEEE 2012 19 EU Standards and technical speciications referred t...

Страница 23: ......

Страница 24: ......

Отзывы: