EPSON Stylus C50/C60/C61/C62
Revision C
Disassembly and Assembly
Disassembly
107
10. Remove the Spur gear 35.2 from the LD roller shaft.
11. Remove the Compression spring, 0.143, and remove the Clutch from the LD roller
shaft.
12. Release one hook for securing the HP/PE sensor, and push the HP/PE sensor from
the side contacting the Main frame by using the tweezers.
Figure 4-34. HP/PE sensor removal
13. Remove the Torsion spring 0.22 for the HP/PE detection levers, and remove the
these levers from the LD roller shaft holder.
Hook
HP/PE sensor
When assembling the HP/PE detection lever to the LD roller shaft
holder,
Make sure to set the Torsion spring 0.22 for the HP/PE
detection levers to the following suitable position.
Figure 4-35. Torsion spring 0.22 for each detection lever
Make sure that the HP/PE detection lever moves smoothly.
When assembling the HP/PE sensor to the LD roller shaft
holder,
Make sure that the HP/PE sensor is correctly fixed by the
hook of the LD roller shaft holder.
Make sure to place the HP/PE sensor cable to the suitable
groove on the LD roller shaft holder.
.
Figure 4-36. HP/PE sensor cable placing position
HP detection lever
Torsion spring 0.22
PE detection lever
Torsion spring 0.22
HP/PE sensor cable
HP/PE sensor
HP/PE sensor cable
Содержание Stylus Color C60
Страница 1: ...EPSONStylusC50 C60 C61 C62 Color Inkjet Printer SEIJ02001 SERVICE MANUAL ...
Страница 11: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 33: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 66: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 93: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 134: ...C H A P T E R 5 ADJUSTMENT ...
Страница 137: ...C H A P T E R 6 MAINTENANCE ...
Страница 144: ...C H A P T E R 7 APPENDIX ...
Страница 182: ......
Страница 183: ......
Страница 184: ......
Страница 185: ......
Страница 186: ......
Страница 187: ......
Страница 188: ......