SC-S30600 Series
Revision B
TROUBLE SHOOTING
Remedies for Service Call Error
41
Confidential
1431
Suction pump
life error
The Pump Cap Unit has reached the end of its service
life. (The total number of revolutions of the Pump
Motor has reached a predetermined limit)
---
and reset the
counter
1432
IC Holder
life error
The IC Holder has reached the end of its service life.
(The total number of times that the holder was
removed from the printer has reached a predetermined
limit)
---
Replace the IC Holder
and reset the
counter
1434
Self-sealing valve
life error
The Self-sealing valve has reached the end of its
service life.
---
Replace the Self-sealing valve
and reset
the counter
1435
Ink Path CR Assy
life error
The Ink Path CR Assy has reached the end of its
service life.
---
Replace the Ink Path CR Assy
and reset
the counter
1411
Pump Cap Unit
undetectable error
Pump Cap Unit failure
Is the sensor cable properly connected?
Replace the Pump Cap Unit.
150C
PG position
undetectable error
When changing the PG, the PG sensor could not
detect the PG position.
1. Is the PG Sensor out of order? Does the light
shielding plate react to the sensor?
2. Do the planetary gearing work normally? Do the
planet gears and outer gears properly engage with
each other?
3. Is the CR Unit out of its home position?
1. Replace the PG Sensor.
2. Replace the APG Assy.
3. Remove any obstacles around the CR Unit home
position. The printer changes the PG with the CR
Unit being at its home position.
1519
APG Motor
oscillation error
The control terminal (Vre terminal) of the APG Motor
driver has shorted out.
1. Is the APG Motor driver on the Main Board
damaged?
2. Is there any foreign materials around the APG
Motor driver?
1. Remove the foreign material.
2. If the error still occurs, replace the Main Board.
151A
APG Motor
overload error
Connection failure of the APG Motor.
Overcurrent to the APG Motor was detected.
APG Motor cable is damaged.
Irregular load
APG encoder failure
APG Motor failure
Is there any problems such as damaged cable in the
connections below?
APG Motor (APG encoder) to Main Board
(CN210/CN23)
Replace the APG Motor.
151B
APG Motor
over speed error
The APG Motor was driven at a speed faster than a
predetermined one during deceleration.
Irregular load
APG encoder failure
APG Motor driver failure
---
1. Replace the APG Motor.
2. Replace the Main Board.
151C
APG Motor
reversing error
The number of occurrences of reversing the APG
Motor has reached a predetermined limit.
The polarity of APG Motor cable is opposite.
APG Motor failure
Is there any problems such as damaged cable in the
connections below?
APG Motor (APG encoder) to Main Board
(CN210/CN23)
Replace the APG Motor.
Code
Error Name
Cause
Check Item
Remedy
Содержание SC-S30600
Страница 1: ...SC S30600Series Large Format Color Inkjet Printer SERVICE MANUAL SEIJ11002 Confidential ...
Страница 9: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 33: ...Confidential C H A P T E R 2 TROUBLESHOOTING ...
Страница 61: ...Confidential C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Страница 198: ...Confidential C H A P T E R 4 ADJUSTMENT ...
Страница 276: ...Confidential C H A P T E R 5 MAINTENANCE ...
Страница 290: ...Confidential C H A P T E R 6 APPENDIX ...